2016
DOI: 10.1103/physrevd.93.061101
|View full text |Cite
|
Sign up to set email alerts
|

Improved dark matter search results from PICO-2L Run 2

Abstract: New data are reported from a second run of the 2-liter PICO-2L C 3 F 8 bubble chamber with a total exposure of 129 kg-days at a thermodynamic threshold energy of 3.3 keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the o… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
164
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 137 publications
(164 citation statements)
references
References 48 publications
(79 reference statements)
0
164
0
Order By: Relevance
“…The NMSSM specific Yukawa couplings λ and κ, the soft Susy breaking terms A λ and A κ , µ and tan β are varied The remaining parameters are still varied in order to find the strict boundaries in the above defined plane. These originate from a dark matter relic density consistent with the WMAP/Planck value Ω DM h 2 = 0.1187 [62,63], allowing for a 10% theory error, and from upper limits on spin-dependent and spin-independent direct detection cross sections from PICO-2L [21], LUX [22,23] and PandaX-II [24,25]. The dark matter relic density and the spin-dependent and spin-independent direct detection cross sections are computed with help of micrOMEGAS 3 [64].…”
Section: Jhep02(2017)051mentioning
confidence: 78%
See 1 more Smart Citation
“…The NMSSM specific Yukawa couplings λ and κ, the soft Susy breaking terms A λ and A κ , µ and tan β are varied The remaining parameters are still varied in order to find the strict boundaries in the above defined plane. These originate from a dark matter relic density consistent with the WMAP/Planck value Ω DM h 2 = 0.1187 [62,63], allowing for a 10% theory error, and from upper limits on spin-dependent and spin-independent direct detection cross sections from PICO-2L [21], LUX [22,23] and PandaX-II [24,25]. The dark matter relic density and the spin-dependent and spin-independent direct detection cross sections are computed with help of micrOMEGAS 3 [64].…”
Section: Jhep02(2017)051mentioning
confidence: 78%
“…It is the purpose of the present paper to investigate in how far this attractive scenario within the NMSSM is tested by the most recent direct dark matter detection experiments PICO-2L [21], LUX [22,23] and PandaX-II [24,25], in combination with searches at the LHC for electroweakinos at run I and, in the future, by the high luminosity (HL) LHC.…”
Section: Jhep02(2017)051mentioning
confidence: 99%
“…4 and 5, respectively. In addition to the 71 Geactivation peaks, the K-shell activation peak from 65 Zn is visible in the Run 1 spectrum at 8.89 keV ee [24]. The Zn was created by cosmic-ray interactions, with production ceasing once the detector was brought underground in 2011, and decayed with a half-life of τ 1=2 ≈ 244d [35].…”
Section: B Data Sets and Previous Resultsmentioning
confidence: 99%
“…For both, the median (90% C.L.) (thick black solid curve) upper limit from CDMSlite Run 2 is compared to other selected direct-detection limits from PANDAX-II (thick-green dotted curve) [61], LUX (thick-green dotdashed curve) [62], XENON100 (thick-green dashed curve) [63], PICO-60 (magenta upward triangles) [64], PICO-2L (magenta downward triangles) [65], PICASSO (purple dot-dashed band) [66], CDEX-0 (thin-red dashed curve) [67,68], and CDEX-1 (thin-red solid curve) [68]. The orange band surrounding the Run 2 result is the 95% uncertainty interval on the upper limit.…”
Section: Fig 32mentioning
confidence: 99%
“…are given by the XENON100 [61][62][63], LUX [64,65], PANDAX-II [66,67] and PICO [68,69]. The XENON1T [70] and LZ [71] will cover wider range in near future.…”
Section: Jhep08(2017)072mentioning
confidence: 99%