1989
DOI: 10.1016/s0021-9673(01)84486-1
|View full text |Cite
|
Sign up to set email alerts
|

Improved cross-axis synchronous flow-through coil planet centrifuge for performing counter-current chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1990
1990
2009
2009

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…9 Separation of gramicidins with CHCl 3benzene-MeOH-water was performed in 1982 71 and of bacitracin with CHCl 3 -95% EtOH-water in 1989. 131 The combination of CHCl 3 -MeOH-water was first reported in 1985. Siderochelin A and pentalenolactone were isolated using CHCl 3 -MeOH-water (7:13:8 and 1:1:1, respectively) by Brill et al 132 This combination proved to be very useful and was used in many subsequent separations throughout the 1980s and 1990s.…”
Section: Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…9 Separation of gramicidins with CHCl 3benzene-MeOH-water was performed in 1982 71 and of bacitracin with CHCl 3 -95% EtOH-water in 1989. 131 The combination of CHCl 3 -MeOH-water was first reported in 1985. Siderochelin A and pentalenolactone were isolated using CHCl 3 -MeOH-water (7:13:8 and 1:1:1, respectively) by Brill et al 132 This combination proved to be very useful and was used in many subsequent separations throughout the 1980s and 1990s.…”
Section: Reviewmentioning
confidence: 99%
“…In fact, the first documented use of DCCC was in the separation of a DNP−amino acid mixture with CHCl 3 −acetic acid−0.1 N aqueous HCl (2:2:1) . Separation of gramicidins with CHCl 3 −benzene−MeOH−water was performed in 1982 and of bacitracin with CHCl 3 −95% EtOH−water in 1989 . The combination of CHCl 3 −MeOH−water was first reported in 1985.…”
Section: Solvent Systems: the Empirical Approachmentioning
confidence: 99%
“…The detailed design of the cross-axis CPC was described elsewhere [37,38]. The apparatus holds a pair of horizontal rotary shafts, symmetrically mounted one on each side of the rotary frame, at a distance of 10 cm from the centrifuge axis as shown in Fig.…”
Section: Apparatusmentioning
confidence: 99%
“…able retention of the stationary phase for viscous polymer phase systems. The detailed design of the x-axis CPC was described elsewhere [9,10]. The present apparatus holds a pair of column holders in the lateral position at 10 cm from the center of the rotary shaft horizontally mounted on the rotary frame at 10 cm from the central axis of the apparatus as shown in Fig.…”
Section: Apparatusmentioning
confidence: 99%