“…TAD is the only validated clinical outcome that was measured (Baumgaertner et al 1995, Güven et al 2010, Hsueh et al 2010, Andruszkow et al 2012). Baumgaertner et al (1995) demonstrated that a TAD of less than 25 mm was the most important factor to minimize the cut-out rate.…”
Section: Discussionmentioning
confidence: 99%
“…TAD is the only validated clinical outcome that was measured (Baumgaertner et al 1995, Güven et al 2010, Hsueh et al 2010, Andruszkow et al 2012). Baumgaertner et al (1995) demonstrated that a TAD of less than 25 mm was the most important factor to minimize the cut-out rate.…”
Section: Discussionmentioning
confidence: 99%
“…To prevent complications of immobilization, fracture fixation should allow early mobilization of the patient with immediate full weight bearing [3]. Since the 1960s, the sliding hip screw and side plate (DHS) has become the standard implant for surgical treatment of intertrochanteric fractures as it allows controlled fracture compression [4,5]. Despite additional modifications, such as trochanteric support plates and antirotational screws, unstable fractures are less successfully treated by this method [3,6].…”
Section: Introductionmentioning
confidence: 99%
“…In summary, a central-posterior placement of the implanted hip screw in the lateral radiographic view and a central-inferior position in the anteroposterior view are recommended by most authors [2,5,11,12]. Furthermore, the quality of fracture reduction described by the neck shaft angle (NSA) has been evaluated [13,14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although this peripheral placement of the helical blade increases the TAD, the TAD is not related with cutout failure 32. In our study, the mean TAD in the I-C group was more than the C-C group and TAD had a positive linear correlation with cyclic loading which leads to fracture displacement and ultimate load to failure 1631–33…”
Section: Discussionmentioning
confidence: 53%