2021
DOI: 10.1007/s10518-021-01277-9
|View full text |Cite
|
Sign up to set email alerts
|

Implications of inter-storey-isolation (ISI) on seismic fragility, loss and resilience of buildings subjected to near fault ground motions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 59 publications
0
6
0
Order By: Relevance
“…A relatively new seismic vibration control solution for higher buildings is inter-storey isolation (ISI). The isolation bearings are positioned at an intermediate level to isolate the upper storey block (USB), which also functions as a non-traditional tuned mass damper (TMD) to the lower storey block (LSB), reducing vibration [57]. The fundamental benefit of inter-story seismic isolation is the blockage of energy flow between the upper and lower stories, making it an effective way to divide the various components of high-rise buildings with distinct uses and, consequently, variable seismic performance needs [58].…”
Section: Rooftop Structuresmentioning
confidence: 99%
“…A relatively new seismic vibration control solution for higher buildings is inter-storey isolation (ISI). The isolation bearings are positioned at an intermediate level to isolate the upper storey block (USB), which also functions as a non-traditional tuned mass damper (TMD) to the lower storey block (LSB), reducing vibration [57]. The fundamental benefit of inter-story seismic isolation is the blockage of energy flow between the upper and lower stories, making it an effective way to divide the various components of high-rise buildings with distinct uses and, consequently, variable seismic performance needs [58].…”
Section: Rooftop Structuresmentioning
confidence: 99%
“…Ferj and Lopez-Garcia [33] compared the fragility curves of a hospital building with and without base isolators. Recently, Saha and Mishra [34] studied the effects of inter-story isolation systems on the seismic fragility of buildings. In most of the aforementioned studies, the focus was on deriving the fragility curve for a specific type of base isolation system.…”
Section: Introductionmentioning
confidence: 99%
“…Liu et al (2018) discovered that viscous fluid dampers can effectively enhance the seismic performance of mid-story isolated structures. Moreover, the application of mid-story isolated structure in the reinforcement of existing structures can effectively lower the seismic response of structures (Li et al, 2014;Ma et al, 2020;Saha and Mishra, 2021;Hur and Park, 2022). Use machine learning methods to predict the occurrence of disasters in different environments.…”
Section: Introductionmentioning
confidence: 99%