2019
DOI: 10.1155/2019/2609235
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of Static Line Voltage Stability Indices for Improved Static Voltage Stability Margin

Abstract: Nowadays, the changes of economic, environment, and regulations are forcing the electric utilities to operate systems at maximum capacity. Therefore, the operation and control of power system to improve the system stability has been receiving a great deal of attention. This paper presents an approach for enhancing the static voltage stability margin and reducing the power losses of the system with voltage security-constrained optimal power flow (VSC-OPF) that is based on static line voltage stability indices. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
21
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(25 citation statements)
references
References 37 publications
(50 reference statements)
3
21
1
Order By: Relevance
“…This work investigated the enhancement of the voltage stability by observing the maximum loadability before the voltage collapse point; however, the line outage contingency condition where the systems mostly require voltage stability enhancement have not been investigated. In [34], four line VSIs were introduced as the objective function in the line outage contingency condition. The maximum loadability values at the voltage collapse point were also demonstrated.…”
Section: Many Techniques and Methods In The Literature Have Beenmentioning
confidence: 99%
“…This work investigated the enhancement of the voltage stability by observing the maximum loadability before the voltage collapse point; however, the line outage contingency condition where the systems mostly require voltage stability enhancement have not been investigated. In [34], four line VSIs were introduced as the objective function in the line outage contingency condition. The maximum loadability values at the voltage collapse point were also demonstrated.…”
Section: Many Techniques and Methods In The Literature Have Beenmentioning
confidence: 99%
“…Kessel [12] developed L-index which is a simple method and has been used as the indicator of the voltage stability of the transmission line. It will give online monitoring of voltage sensitivity at all load buses with sufficient accuracy.…”
Section: Methodology To Identify Weak Busmentioning
confidence: 99%
“…The P-Vcurve, as indicated in Figure 2, represents a non-linear relationship between the active power and voltage. It is used to locate the maximum allowable safe loading margin (in MW) from the operating point to the critical voltage for a specific load bus(es) in a power network [45][46][47]. The PV-curve can be calculated by using a series of power-flow solutions for different load levels.…”
Section: Drawing Of the P-vcurvementioning
confidence: 99%