Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap

Abstract: Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
11
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 50 publications
1
11
0
Order By: Relevance
“…Figure b shows the experimentally observed relationship between secular frequency and beat frequency using frequency tagging, and converting secular frequency to m / z via Mathieu parameters gives the plot in Figure c. The calibration is shown in blue and the experimentally observed values in red. Lastly, product ions are ejected from the ion trap within hundreds of microseconds of their respective precursor ions being fragmented, and hence, their relationship is preserved in time, just as they were preserved in our implementation of precursor and neutral loss scans. , …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Figure b shows the experimentally observed relationship between secular frequency and beat frequency using frequency tagging, and converting secular frequency to m / z via Mathieu parameters gives the plot in Figure c. The calibration is shown in blue and the experimentally observed values in red. Lastly, product ions are ejected from the ion trap within hundreds of microseconds of their respective precursor ions being fragmented, and hence, their relationship is preserved in time, just as they were preserved in our implementation of precursor and neutral loss scans. , …”
Section: Resultsmentioning
confidence: 99%
“…Lastly, product ions are ejected from the ion trap within hundreds of microseconds of their respective precursor ions being fragmented, and hence, their relationship is preserved in time, just as they were preserved in our implementation of precursor and neutral loss scans. , …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Additional modifications were made to apply externally controlled low voltage auxiliary waveforms individually to both the x - and y -rod pairs . Nitrogen was used instead of helium as the bath gas in order to improve sensitivity . An uncalibrated ion gauge reading of 1.5 × 10 –5 Torr was used in the experiments.…”
Section: Experimental Sectionmentioning
confidence: 99%
“…28 Nitrogen was used instead of helium as the bath gas in order to improve sensitivity. 29 An uncalibrated ion gauge reading of 1.5 × 10 −5 Torr was used in the experiments.…”
Section: ■ Introductionmentioning
confidence: 99%