2005
DOI: 10.1016/j.nima.2005.01.102
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of neutron tomography around the Algerian Es-Salam research reactor: preliminary studies and first steps

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Tritium activity concentrations are found to vary significantly between the various metal samples investigated (Table ). The highest activity concentrations were observed for irradiated aluminum, but high activity concentrations were also observed, unsurprisingly, for the middle B 4 C (boron carbide) layer of Boral. For nonirradiated metals, the highest activity concentration was associated with stainless steel and the lowest with Cu. The relative activity concentrations for different metal samples depended on the specific metal, its ambient 3 H concentration, the neutron flux (for irradiated metals), and the duration of exposure.…”
Section: Resultsmentioning
confidence: 94%
“…Tritium activity concentrations are found to vary significantly between the various metal samples investigated (Table ). The highest activity concentrations were observed for irradiated aluminum, but high activity concentrations were also observed, unsurprisingly, for the middle B 4 C (boron carbide) layer of Boral. For nonirradiated metals, the highest activity concentration was associated with stainless steel and the lowest with Cu. The relative activity concentrations for different metal samples depended on the specific metal, its ambient 3 H concentration, the neutron flux (for irradiated metals), and the duration of exposure.…”
Section: Resultsmentioning
confidence: 94%
“…According to the manufacturer specifications, this system has a maximum intrinsic spatial resolution of 200 µm (171.5 µm calculated). All necessary experiments were performed at the neutron radiography facility of the Es-Salam research reactor (Kharfi, et al, 2005). To achieve this task, a MatLab code was developed.…”
Section: Temporal and Spatial Resolution Limit Study Of A Radiographimentioning
confidence: 99%
“…It is a two-dimensional mxn array of non-negative integers (gray levels) [18]. The gray level value represents the relative linear attenuation coefficient of the object.…”
Section: Application To Neutron Radiography Imagesmentioning
confidence: 99%