2019 International Conference on Engineering and Emerging Technologies (ICEET) 2019
DOI: 10.1109/ceet1.2019.8711841
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of Micro Controller Based Electromechanical Over Current Relay for Radial Feeder Protection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 3 publications
0
4
0
1
Order By: Relevance
“…Time Setting menentukan kecepatan waktu pengoperasian relay, sementara pengaturan PS menentukan batas arus maksimum yang dapat melalui beban. Dalam purwarupa OCR pada penelitian ini, memiliki input Irelay (input current), konstanta time setting dan PS (Plug Setting/Pick-up) yang dijabarkan pada Gambar 1 [7], [8]. Karakteristik Inverse Definite Minimum Time (IDMT), Very Inverse, Extremely Inverse, dan Long Time Inverse memiliki karakteristik semakin besar suatu gangguan, semakin cepat harus ditangani untuk menghindari kerusakan pada peralatan.…”
Section: Pembahasan Dan Hasil Pengujianunclassified
“…Time Setting menentukan kecepatan waktu pengoperasian relay, sementara pengaturan PS menentukan batas arus maksimum yang dapat melalui beban. Dalam purwarupa OCR pada penelitian ini, memiliki input Irelay (input current), konstanta time setting dan PS (Plug Setting/Pick-up) yang dijabarkan pada Gambar 1 [7], [8]. Karakteristik Inverse Definite Minimum Time (IDMT), Very Inverse, Extremely Inverse, dan Long Time Inverse memiliki karakteristik semakin besar suatu gangguan, semakin cepat harus ditangani untuk menghindari kerusakan pada peralatan.…”
Section: Pembahasan Dan Hasil Pengujianunclassified
“…Mohamed Zellagui and his team develop a project about the impact of GTO Controlled Series Capacitor (GCSC) parameters on the Inverse Definite Minimum Time (IDMT) (DOCR) centered on the Global Electro technical Commission (IEC) standards. The DOCR is used to secure a single 400 kV transmission system in Algeria's transmission network that connects to the Algerian Company of Electrical and Gas (Group Sonelgaz) [1]. A research considering the designing of the electromechanical and microcontroller (Arduino) based relays an educational lab trainer to compare the behavior of both relays in overcurrent protection of radial feeder which was designed for protection of two sections so that the concept of primary and secondary protection is observed [4].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Not only for economic reasons but also consumers, the ability of the protection system is required simply to expect "reliable" service. The defensive relay is most commonly combined with the Circuit Breaker relay so that the unstable state in the device can be isolated [1].…”
Section: Introductionmentioning
confidence: 99%
“…A fault in the circuit can be obtained due to the failure that cognizable with the ordinary current flow. When the system insulation fails due to low impedance itinerary either between phase (s) to ground or phases a short [13][14][15][16][17]. Circuit fault will occur; this short circuit faults are classified as [18]:…”
Section: Faults and Classificationsmentioning
confidence: 99%