2010 4th International Power Engineering and Optimization Conference (PEOCO) 2010
DOI: 10.1109/peoco.2010.5559251
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of DG for loss minimization and voltage profile in distribution system

Abstract: This paper presents the effects of DG on the performance of an existing distribution network in terms of voltage stability, loss minimization and voltage profile. In this study, a new program was developed based on Artificial Immune System optimization technique in order to determine the optimal size of distributed generator. Various loading conditions were tested in order to evaluate the effectiveness of the proposed technique in determining the optimal size of the distributed generator. The suitable location… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…As shown in Table I, in [1], [4][5][6][7][8][9][10][11][12][13], the planning problem is done either with one or multi level load models, and moreover only one load type is considered in their formulations. The drawback of these assumptions is that there are various load types in distribution networks which their profiles are different.…”
Section: Why New Model For Dg Planning?mentioning
confidence: 99%
“…As shown in Table I, in [1], [4][5][6][7][8][9][10][11][12][13], the planning problem is done either with one or multi level load models, and moreover only one load type is considered in their formulations. The drawback of these assumptions is that there are various load types in distribution networks which their profiles are different.…”
Section: Why New Model For Dg Planning?mentioning
confidence: 99%
“…With fast infiltration of DG into distribution systems, it is basic to evaluate its effects to power system precisely so that these DG units be connected in a way that avoid degradation of power quality, flexibility in control of the utility system and increase reliability. Then again, DG can possibly enhance distribution system performance and it ought to be encouraged [9][10][11][12][13][14]. In this way, it has turned out to be critical to study changes that DG acquires with a change its area or size of DG.…”
Section: Introductionmentioning
confidence: 99%
“…It is known that the DG can help to reduce the utilization of fossil fuel, environmental impact and electrical line power losses. It also helps to improve power system voltage profile [2]. Unfortunately, installation at unsuitable location and size of the DG could cause effect in the opposite way such as increase of electrical line power losses.…”
Section: Introductionmentioning
confidence: 99%