2015
DOI: 10.1117/12.2190153
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of an enhanced, permanently installed neutron activation diagnostic hardware for NIF

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…Studies on warm, gas-filled exploding pusher target implosions reported significant anisotropy attributed to target alignment [57], target mounting [58], capsule defects [59], and non-uniform illumination [60]. For example, the effect of dropping two of the 48 NIF laser quads leads to substantial asymmetry in density and implosion velocity without precise redistribution of the remaining laser energy.…”
Section: Neutron Activation Diagnostics (Nad)mentioning
confidence: 99%
See 1 more Smart Citation
“…Studies on warm, gas-filled exploding pusher target implosions reported significant anisotropy attributed to target alignment [57], target mounting [58], capsule defects [59], and non-uniform illumination [60]. For example, the effect of dropping two of the 48 NIF laser quads leads to substantial asymmetry in density and implosion velocity without precise redistribution of the remaining laser energy.…”
Section: Neutron Activation Diagnostics (Nad)mentioning
confidence: 99%
“…An FNADs system based on a lanthanum bromide scintillators and compact gamma spectrometers installed in the target bay is being developed to provide immediate postshot readout of yield [58]. This system will have additional capability to measure multiple DT neutron reactions and other neutron source terms, such as TT and DD fusion reaction neutrons [59,60].…”
Section: Neutron Activation Diagnostics (Nad)mentioning
confidence: 99%
“…Additionally, spatially-distributed flange-mounted NADs (FNADs) measure, with nearly identical systematic uncertainties, primary DT neutron emission to infer a whole-sky neutron field [20]. Real-time NADs, based on a lanthanum bromide scintillator and compact gamma spectrometer installed in the target bay, are being developed to provide immediate postshot readout of yield in a modular and expandable integrated system design [21]. This system will have additional physics capability to measure multiple DT neutron reactions [22] and other neutron source terms [23].…”
Section: Neutron Activation Diagnostics (Nads)mentioning
confidence: 99%