Implementation of a Smart Power Conditioning System for Energy Storage System with a Novel Seamless Transfer Strategy

Abstract: Implementation of a smart power conditioning system with a novel seamless transfer method for an energy storage system (ESS) was proposed in this paper. The power conditioning system is to control the power quality or protect the grid system. Therefore, it requires various functions. One of the these functions, the uninterruptible power supply (UPS) function, was applied to proposed power conditioning system. In order for the grid-interactive power conditioning system to continuously supply power to the load, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 34 publications
(40 reference statements)
0
1
0
Order By: Relevance
“…In spite of this, the MG system is usually connected to the utility through switches consisting of thyristors rather than IGBTs, GTOs etc., in AC bus from current-carrying capability and the practicability point of view, especially in high voltage and current occasions [27,28]. In [29][30][31], it takes from 1/4 to 1/2 line cycle for the MG system to disconnect from the utility at zero crossing of the grid current and 5 line cycle to ensure the whole procedure at most, which is far beyond the requirement of power continuity for sensitive loads [32]. Even worse, power quality of the MG system may be further deteriorated by the turn-off delay.…”
Section: Introductionmentioning
confidence: 99%
“…In spite of this, the MG system is usually connected to the utility through switches consisting of thyristors rather than IGBTs, GTOs etc., in AC bus from current-carrying capability and the practicability point of view, especially in high voltage and current occasions [27,28]. In [29][30][31], it takes from 1/4 to 1/2 line cycle for the MG system to disconnect from the utility at zero crossing of the grid current and 5 line cycle to ensure the whole procedure at most, which is far beyond the requirement of power continuity for sensitive loads [32]. Even worse, power quality of the MG system may be further deteriorated by the turn-off delay.…”
Section: Introductionmentioning
confidence: 99%