2022
DOI: 10.35882/ijahst.v2i2.1
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of a Microcontroller Arduino for Portable Peak Expiratory Flow Rate to Examine the Lung Health

Abstract: A peak flow meter will measure the ability to push air out of the lungs; the lungs are one of the body's most vital organs. The commonly used method is to deploy a peak flow meter, which uses mechanical systems. This mechanical system is prone to a high error rate of reading, and as a result, a more accurate and reliable means becomes inevitable. This paper describes the design and implementation of a micro-controller-based portable peak flow meter, which can be used to provide accurate data for the diagnosis … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…The maximum pressure value that the sensor can read is 99.61 kPa. The maximum pressure value obtained in the test shows that the sensor worked well under the characteristics of the MPX5100DP sensor that has a maximum pressure value of 100 kPa as in [21], [22]. There are, however, other MEMS piezoelectric absolute pressure sensors that can also be used for Spirometers, such as the STMicro LPS22HH, LPS22HB, and the Bosch BMP388, with the LPS22HH showing the best performance [23].…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The maximum pressure value that the sensor can read is 99.61 kPa. The maximum pressure value obtained in the test shows that the sensor worked well under the characteristics of the MPX5100DP sensor that has a maximum pressure value of 100 kPa as in [21], [22]. There are, however, other MEMS piezoelectric absolute pressure sensors that can also be used for Spirometers, such as the STMicro LPS22HH, LPS22HB, and the Bosch BMP388, with the LPS22HH showing the best performance [23].…”
Section: Resultsmentioning
confidence: 99%
“…The average FVC accuracy from both measurements was 97.11%, while the average FEV1 accuracy was 97.07%. The performance of this proposed system is as good as [19], [21], [22] Table 4, which uses an absolute pressure sensor to measure the lung volume using pressure-volume method with a wireless communication advantage. However, Grunfeld [23] suggests potentially using a lower-price sensor, LPS22HH or LPS22HB, to reduce the spirometer cost.…”
Section: Issn: 2088-8708 mentioning
confidence: 99%
See 3 more Smart Citations