2017
DOI: 10.1049/joe.2017.0609
|View full text |Cite
|
Sign up to set email alerts
|

Implementation and value of power hardware in the loop testing bed for wind turbines integrated into grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…In most cases, the greater number of outputs is, the more converters that the grid emulators can test; the greater number of inputs is, the more complex spatial configurations that the grid emulators can reflect. In this case, the spatial configurations of commonly seen ac grid for emulation can be categorized into single-inputsingle-output (SISO) type [54]- [58], multi-input-single-output (MISO) type [59]- [66], and multi-input-multi-output (MIMO) type [71]- [83].…”
Section: A Spatial Configurationmentioning
confidence: 99%
“…In most cases, the greater number of outputs is, the more converters that the grid emulators can test; the greater number of inputs is, the more complex spatial configurations that the grid emulators can reflect. In this case, the spatial configurations of commonly seen ac grid for emulation can be categorized into single-inputsingle-output (SISO) type [54]- [58], multi-input-single-output (MISO) type [59]- [66], and multi-input-multi-output (MIMO) type [71]- [83].…”
Section: A Spatial Configurationmentioning
confidence: 99%
“…897-905 This is an open access article published by the IET under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/) system with a proper representation of the POD effects. Moreover, the method is experimentally validated on an 18-level MMC using a power hardware in the loop (PHIL) approach, which is a technique for testing power equipment under realistic grid conditions [17,18].…”
Section: Introductionmentioning
confidence: 99%
“…Unlike [12], this paper uses a multi‐machine system with a proper representation of the POD effects. Moreover, the method is experimentally validated on an 18‐level MMC using a power hardware in the loop (PHIL) approach, which is a technique for testing power equipment under realistic grid conditions [17, 18].…”
Section: Introductionmentioning
confidence: 99%
“…The Controller Hardware in the Loop (CHIL) simulation is another type of HIL simulation which is used for low-level digital or analogue testing [9]. Both CHIL and PHIL been discussed extensively and used in different power applications [8][9][10][11][12][13][14][15][16][26][27][28][29].…”
Section: Introductionmentioning
confidence: 99%