2021
DOI: 10.1016/j.jpedsurg.2021.03.008
|View full text |Cite
|
Sign up to set email alerts
|

Implementation and acceptance rates of a specially designed vacuometer for the vacuum bell treatment of pectus excavatum.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 8 publications
0
1
0
Order By: Relevance
“…Moreover, personalized treatment is urgently needed to find suitable candidates, improve treatment compliance, and improve outcomes. In previous studies, a simple change in the use time, pressure, or frequency of VB during the treatment period in all patients may not address the conflict between compliance and the treatment protocol ( 14 , 15 , 21 , 22 ). Although prolonged usage time may be associated with better outcome, it may result in poor treatment compliance and the discontinuation of VB therapy.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, personalized treatment is urgently needed to find suitable candidates, improve treatment compliance, and improve outcomes. In previous studies, a simple change in the use time, pressure, or frequency of VB during the treatment period in all patients may not address the conflict between compliance and the treatment protocol ( 14 , 15 , 21 , 22 ). Although prolonged usage time may be associated with better outcome, it may result in poor treatment compliance and the discontinuation of VB therapy.…”
Section: Discussionmentioning
confidence: 99%
“…It has been observed that pressures above 300 mbar cause pain and do not provide better results (5,9) . Vacuum pressure measurement devices coupled to the bell have been recently developed, allowing pressure to be increased in a gradual and controlled fashion (10,11) .…”
Section: Discussionmentioning
confidence: 99%
“…A treatment initiation protocol has been recently published, with a gradual increase in time and pressure, which is controlled with a measuring device coupled to the VB -a vacuum gauge. This protocol lasts for 6 months and seemingly reduces complications, improves tolerance, and increases treatment adhesion (10) . Our initiation protocol is similar to that used by most authors.…”
Section: Discussionmentioning
confidence: 99%
“…Se ha observado que presiones superiores a 300 mbar causan dolor y no se asocian a mejores resultados (5,9) . Recientemente se han desarrollado medidores de presión de succión acoplados a la campana que permiten su incremento de forma gradual y controlada (10,11) .…”
Section: Discussionunclassified
“…Recientemente se ha publicado un protocolo de inicio de tratamiento con incremento gradual de tiempo y presión, que es controlada con un medidor acoplado a la CS denominado vacuómetro. Este protocolo tiene una duración de 6 meses y parece reducir las complicaciones, mejorar la tolerancia y aumentar la adherencia al tratamiento (10) . Nuestro protocolo de inicio es similar al utilizado por la mayoría de los autores.…”
Section: Discussionunclassified