2016
DOI: 10.1016/j.jse.2016.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Implant positioning in reverse shoulder arthroplasty has an impact on acromial stresses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
57
0
3

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
3
2

Relationship

1
7

Authors

Journals

citations
Cited by 113 publications
(66 citation statements)
references
References 29 publications
1
57
0
3
Order By: Relevance
“…Other studies associated the position of the centre of rotation (COR) and the design of the reverse prosthesis with scapula fractures [26,29,44]. Schenk et al [29] reported an increase of acromial fractures with high medialization and little distalization of the COR.…”
Section: Discussionmentioning
confidence: 99%
“…Other studies associated the position of the centre of rotation (COR) and the design of the reverse prosthesis with scapula fractures [26,29,44]. Schenk et al [29] reported an increase of acromial fractures with high medialization and little distalization of the COR.…”
Section: Discussionmentioning
confidence: 99%
“…Currently, a PubMed search of "reverse shoulder arthroplasty finite element" returns 16 total articles, including two articles generated by this lab. Many of these articles focus on glenosphere fixation and the stresses generated by the fixation in the glenoid region, as well as micromotion of the glenoid fixation [69][70][71][72][73][74][75][76][77][78]. Although such research is important in ensuring the safety of glenoid fixation, the models used to study glenosphere fixation are fairly simplistic, especially when compared to other orthopaedic and arthroplasty research available in the literature [79][80][81][82][83].…”
Section: Rsa Fe Modelingmentioning
confidence: 99%
“…La carga de 400 N correspondió a la carga más grande observada durante la abducción (Langohr, et al, 2016). Wong, et al (2016) utiliza una metodología similar, crearon un modelo computacional para calcular los vectores de fuerza a través de la abducción de 7 secciones del deltoides, para rezalizar el modelo se utiliza un arco de movimiento de abducción cada 15°, entre 0° y 120°.…”
Section: Método De Elementos Finitos Para Modelos De Artroplastia Invunclassified
“…La reducción del ángulo del cuello humeral y de la profundidad de la copa redujeron el área de contacto y aumentaron el estrés pico de contacto. Wong, et al (2016) Evaluar el efecto de la posición del implante húmero y glenoideo RSA sobre las tensiones acromiales.…”
Section: Referenciaunclassified
See 1 more Smart Citation