Implant-Abutment Connection Designs for Anterior Crowns

Abstract: Reliability was higher for the EH and MT relative to IH groups, whereas the characteristic strength was significantly higher for implants with MT connection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
38
2
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 28 publications
(42 citation statements)
references
References 30 publications
(28 reference statements)
1
38
2
1
Order By: Relevance
“…The most frequent causes are surgical trauma, microgaps, peri-implantitis and immediate loading (21)(22)(23). The results of this study are probably related to the presence of microgaps between the External Hexagon implant and abutment, in contrast to the intimate matching observed between the Morse Taper components (9,10). This accurate fit provides better sealing against bacterial microleakage and stability between implant and abutment, which may preserve the peri-implant tissues (9,13).…”
Section: Discussioncontrasting
confidence: 51%
See 2 more Smart Citations
“…The most frequent causes are surgical trauma, microgaps, peri-implantitis and immediate loading (21)(22)(23). The results of this study are probably related to the presence of microgaps between the External Hexagon implant and abutment, in contrast to the intimate matching observed between the Morse Taper components (9,10). This accurate fit provides better sealing against bacterial microleakage and stability between implant and abutment, which may preserve the peri-implant tissues (9,13).…”
Section: Discussioncontrasting
confidence: 51%
“…The platform design is another relevant feature for biomechanical and esthetic success of this restoration (9). In external joints, microgaps between the implant and abutment are found, in contrast to the implants with tapered internal joint; such as Morse Taper, which exhibits intimate matching between the components (9,10). This accurate fit provides better sealing against bacterial microleakage between the implant and abutment, preserving the peri-implant tissues (9).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Historically, the external hexagon connection was designed to provide a rotational torque transferring mechanism for implant placement [4,5]. Reversibility and an anti-rotational mechanism are some advantages of this connection.…”
Section: Introductionmentioning
confidence: 99%
“…However, the external hexagon allows the existence of a microgap in the implant-abutment interface. Besides, this system is less favorable for stress distribution and has lower stability when compared to internal connection, which increases the stress over the abutment screw and micromovements during loading [4][5][6].…”
Section: Introductionmentioning
confidence: 99%