2013
DOI: 10.1016/j.bios.2013.03.050
|View full text |Cite
|
Sign up to set email alerts
|

Impedimetric microbial sensor for real-time monitoring of phage infection of Escherichia coli

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…Isothermal amplification and RT-PCR, generate very rapid results, saving hours of sample analysis time and can be developed inexpensively into sensitive, specific tools that are easy to operate. Biosensors may be seen as a future gold standard for virus detection as they potentially can be developed inexpensively into simple, sensitive and specific analytical tools with the ability of very rapid analysis of multiple samples compared to the conventional methods (Altintas & Tothill 2013, Cheng et al, 2013. However, more often there are obstacles with recognition molecules such as steric hindrance, denaturation and non-specific binding to nontarget molecules.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Isothermal amplification and RT-PCR, generate very rapid results, saving hours of sample analysis time and can be developed inexpensively into sensitive, specific tools that are easy to operate. Biosensors may be seen as a future gold standard for virus detection as they potentially can be developed inexpensively into simple, sensitive and specific analytical tools with the ability of very rapid analysis of multiple samples compared to the conventional methods (Altintas & Tothill 2013, Cheng et al, 2013. However, more often there are obstacles with recognition molecules such as steric hindrance, denaturation and non-specific binding to nontarget molecules.…”
Section: Discussionmentioning
confidence: 99%
“…The limitations of these as POCT methods are currently their high operation costs and lower specificity/sensitivity due to the possibilities of non-specific binding or hybridization that may occur during amplification. To date microarray applications are limited to certain laboratories (Cheng et al, 2013) but there is increasing awareness and interest in these arrays or panels for multiplex analysis.…”
Section: Discussionmentioning
confidence: 99%
“…It is a three-electrode system wherein the working and counter electrodes are made of gold, while the reference electrode and electric contacts are made of silver. The working electrode area of the Au-SPE was pre-treated as reported in related literature [15,19]. Gold disk electrodes were polished with 0.3 and 0.5 µm alumina slurry, rinsed with water, and dried under flowing nitrogen gas.…”
Section: Preparation Of Bacteriophagementioning
confidence: 99%
“…Traditional plaque assays have been extensively used in the detection and quantification of coliphages in water (Grabow and Coubrough, 1986). Despite their usage widely, their application is limited by the time-consuming procedures, tediousness in real time operation and it is not feasible for the detection of non-lytic phages (Cheng et al, 2013). While for the detection of fecal indicators, detection methods include the multiple tube fermentation (method of most probable number) or membrane filtration (Rompré et al, 2002).…”
Section: A11 Backgroundmentioning
confidence: 99%