2015
DOI: 10.1016/j.snb.2015.03.077
|View full text |Cite
|
Sign up to set email alerts
|

Impedimetric and stripping voltammetric determination of methamphetamine at gold nanoparticles-multiwalled carbon nanotubes modified screen printed electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(18 citation statements)
references
References 63 publications
(70 reference statements)
0
18
0
Order By: Relevance
“…The LOD compares favourably with that obtained using indirect electrochemistry with 1,2-naphthoquinone-4-sulfonate [ 16 ], and it is considerably higher than the LODs obtained using direct electrochemical methods [ 13 15 ], although all these methods use aqueous solution and not undiluted saliva. Use of microelectrodes should provide greater sensitivity of response, since increased mass transport of MAMP to the electrode should result in increased peak heights i.e.…”
Section: Resultsmentioning
confidence: 86%
See 1 more Smart Citation
“…The LOD compares favourably with that obtained using indirect electrochemistry with 1,2-naphthoquinone-4-sulfonate [ 16 ], and it is considerably higher than the LODs obtained using direct electrochemical methods [ 13 15 ], although all these methods use aqueous solution and not undiluted saliva. Use of microelectrodes should provide greater sensitivity of response, since increased mass transport of MAMP to the electrode should result in increased peak heights i.e.…”
Section: Resultsmentioning
confidence: 86%
“…There are only a few reports of the electrochemical sensing of amphetamines, and there are no reports of the determination of amphetamines in undiluted saliva using disposable electrochemical sensors. Electrochemical sensing of methamphetamine by direct oxidation has been reported at a pretreated pencil graphite electrode [LOD 50 nM (7.5 ng/mL) in aqueous solution, response time >10 min] [ 13 ], at a self-assembled boron-doped diamond electrode [LOD 50 nM (7.5 ng/mL) in aqueous solution, response time not given] [ 14 ], and in alkaline solution using a gold nanoparticle-multiwalled carbon nanotube modified screen printed electrode [LOD 0.3 nM (0.05 ng/mL), response time not given] [ 15 ]. The indirect electrochemical detection of amphetamine in saliva has been reported using 1,2-naphthoquinone-4-sulfonate at an edge plane pyrolytic graphite electrode [LOD 41 μM (6.2 μg/mL) in aqueous solution, response time not given] [ 16 ].…”
Section: Introductionmentioning
confidence: 99%
“…The screen printed electrodes (SPE) are simple, low cost, portable, small sized and capable of mass production [15]. The reduced size of the SPEs lowers the sample volume down to 30-40 L, which is advantageous especially in the analysis of biological samples and can be easily integrate in miniaturized portable devices [16]. The SPEs are very versatile since the composition of the printing inks could be modified with several substances such as metals, enzymes, polymers or complexing agents [17].…”
Section: Introductionmentioning
confidence: 99%
“…The energy transfer coefficient α for the bare and MWCNT-modified GCE was 0.47 and 0.07, respectively, and for various concentrations of Au(NP)-MWCNT-modified GCEs, it was found in the range from 0.15 to 0.22. Ideally, α varies from 0 to 1 and classifies the type of reaction, 52 that is, irreversible if α is close to 0; reversible if it is close to 1; and quasi-reversible in case α is close to 0.5. It was observed that in the present case, the reaction was quasi-reversible for the bare GCE, became irreversible for MWCNT-modified GCE, but for Au(NP)-MWCNT nanohybrid-modified GCE, reaction again became quasi-reversible.…”
Section: Effect Of Scan Ratementioning
confidence: 99%