2018
DOI: 10.1021/acsenergylett.8b00465
|View full text |Cite
|
Sign up to set email alerts
|

Impedance Spectroscopy Measurements in Perovskite Solar Cells: Device Stability and Noise Reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
101
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 108 publications
(104 citation statements)
references
References 33 publications
1
101
0
Order By: Relevance
“…IS measurements are performed on complete, planar PSCs with various UVO treatments to evaluate variations in V oc , FF, and PCE. Measurements were carried out under Xenon lamp (intensity 100 mW cm −2 ) illumination over a wide range of applied voltages and frequencies (from 0 up to V oc and from 1 MHz to 0.1 Hz) . The fitting has been performed using the equivalent circuits discussed by Yoo et al and the recombination resistance ( R rec ) has been approached by addition of the resistances of high frequency and low frequency (lf) semicircles obtained in the Nyquist plot, (Figure S5, Supporting Information).…”
Section: Figures Of Merits Jsc Ff Voc and Pce Expressed As Mean mentioning
confidence: 99%
“…IS measurements are performed on complete, planar PSCs with various UVO treatments to evaluate variations in V oc , FF, and PCE. Measurements were carried out under Xenon lamp (intensity 100 mW cm −2 ) illumination over a wide range of applied voltages and frequencies (from 0 up to V oc and from 1 MHz to 0.1 Hz) . The fitting has been performed using the equivalent circuits discussed by Yoo et al and the recombination resistance ( R rec ) has been approached by addition of the resistances of high frequency and low frequency (lf) semicircles obtained in the Nyquist plot, (Figure S5, Supporting Information).…”
Section: Figures Of Merits Jsc Ff Voc and Pce Expressed As Mean mentioning
confidence: 99%
“…IS has emerged as a powerful and unique technique for investigation of various processes taking place in the PSCs under illumination and in dark and how they are influenced by other layers. Research efforts have been made to demonstrate the use of IS to compare the performance of perovskite optoelectronics …”
Section: Is Characteristics For Photovoltaic Devicesmentioning
confidence: 99%
“…The other well-dened operating point would be a voltage of 0 V (J SC ). However, the impedance at 0 V is not very useful because it increases to very large magnitudes and the time constants are much larger, which means that the measurement time increases to impractical timescales and the whole spectrum can hardly be measured accurately as demonstrated by Pitarch-Tena et al 8 A consistent measurement procedure that provides both consistent EIS and performance in one simple measurement routine is yet to be proposed.…”
Section: General Consequences For Impedance Studies On Pscmentioning
confidence: 99%
“…The major driving force to employ EIS for PSCs is the lack of knowledge about the details of the reversible and irreversible, the benecial and detrimental processes that occur in PSCs with respect to operating conditions and material compositions. [4][5][6][7][8] Conveniently, the features to be identied by EIS are in the practical frequency range for ordinary EIS (1 MHz to $50 mHz). However, the limited stability of PSC has hampered a consistent analysis and the establishment of a physically based equivalent circuit model (ECM) so far.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation