Impedance Cardiography as a Noninvasive Method of Monitoring Cardiac Function and Other Parameters of the Cardiovascular System*

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
204
0
7

Year Published

1975
1975
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 372 publications
(216 citation statements)
references
References 3 publications
1
204
0
7
Order By: Relevance
“…Impedance cardiology was used (Minnesota Impedance Cardiograph, Model 304B: Instrumentation for Medicine, Greenwich, CN, USA) to estimate stroke volume (SV) using the formula proposed by Kubicek et al, 17 and an electrocardiogram (Amlab Physiograph) was used to measure heart rate (HR). Blood pressure (BP) was monitored continuously on a beat-to-beat basis by a Finapres (Model Ohmeda 2300: Ohmeda, Madison, WI, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Impedance cardiology was used (Minnesota Impedance Cardiograph, Model 304B: Instrumentation for Medicine, Greenwich, CN, USA) to estimate stroke volume (SV) using the formula proposed by Kubicek et al, 17 and an electrocardiogram (Amlab Physiograph) was used to measure heart rate (HR). Blood pressure (BP) was monitored continuously on a beat-to-beat basis by a Finapres (Model Ohmeda 2300: Ohmeda, Madison, WI, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The first derivative of the impedance change (associated with ventricular contraction) was used to calculate stroke volume, using the Kubicek equation. [24][25][26] TPR was calculated in TPR units by dividing mean arterial BP by cardiac output. Arm regional vascular resistance (AVR) was calculated per 100 ml tissue/min in PRU units.…”
Section: Methodsmentioning
confidence: 99%
“…BI signals are recorded first in the chest and then in the thigh with two pairs of surface ECG electrodes attached to a four-electrode impedance device (PhysioFlow PF-05 Lab1, Manatec Laboratories, Paris, France). 20,21 For example, a very low electrical current at high frequency (3.8 mA, 75 kHz) was administered through the first pair of electrodes at the chest wall (electrodes 1 and 4), and the differential electrical potential was recorded by the second pair (electrodes 2 and 3) (see refs. [22][23][24][25].…”
Section: Regional Aostiff Measurementsmentioning
confidence: 99%