2022
DOI: 10.1049/rpg2.12529
|View full text |Cite
|
Sign up to set email alerts
|

Impacts of integration of very large‐scale photovoltaic power plants on rotor angle and frequency stability of power system

Abstract: The increase in penetration of large-scale renewable generation significantly affects power system characteristics. Thus, it is necessary to assess the steady state and dynamic performance of a power system for different installing scenarios of renewable power plants such as photovoltaic (PV) ones. The paper specifically investigates the impacts of very large-scale photovoltaic (VLS-PV) generation on the power system dynamic performance including rotor-angle and frequency stabilities. For this purpose, a detai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…Using such models and actual power grid data, the influence is analyzed through eigenvalues, voltage stability and transient stability. Rezaei J and his research team in (Rezaei et al, 2022) investigated the influence of exceptionally large solar energy generation on the dynamic characteristics of power grids, including rotation speed and reliability requirements. Therefore, a detailed equivalent dynamic model and corresponding controller are established.…”
Section: Introductionmentioning
confidence: 99%
“…Using such models and actual power grid data, the influence is analyzed through eigenvalues, voltage stability and transient stability. Rezaei J and his research team in (Rezaei et al, 2022) investigated the influence of exceptionally large solar energy generation on the dynamic characteristics of power grids, including rotation speed and reliability requirements. Therefore, a detailed equivalent dynamic model and corresponding controller are established.…”
Section: Introductionmentioning
confidence: 99%
“…As demonstrated, the benefits of PV integration are strongly related to the factors such as the node criticality, type, location and penetration of PVs, as well as types of transients. The impacts on the transient stability are analyzed in the 39-bus and 118-bus systems, under different grounding fault locations and various reactive power control strategies (Rezaei et al, 2022). It is found that they depend on the disturbance types, PV installation locations, and network structure.…”
mentioning
confidence: 99%
“…Вeликомaсштaбні фотоeлeктричні устaновки (VLS-PV) цінують зa високу eфeктивність, коли їхня aрхітeктурa є оновлювaною тa нaдійною. Крім того, витрaти нa пeрeтворeння eнeргії є низькими, a устaновкa VLS-PV здaтнa пом'якшити нaслідки чaсткового зaтінeння [3,4].…”
unclassified