2017
DOI: 10.1016/j.ajo.2017.06.018
|View full text |Cite
|
Sign up to set email alerts
|

Impacts of Implantable Collamer Lens V4c Placement on Angle Measurements Made by Optical Coherence Tomography: Two-Year Follow-up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
34
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(38 citation statements)
references
References 30 publications
4
34
0
Order By: Relevance
“…IOP also recovered to a normal level at 24 h postoperative. In 2 prospective studies published in 2016 [17] and 2017 [11], ACA was measured 1 month after V4c ICL implantation and found to have been narrowed by 34-42% and 39-45%, respectively. In those studies, the ACA at 1 month postoperative was more open than the early ACA at 1 h postoperative in our study.…”
Section: Discussionmentioning
confidence: 99%
“…IOP also recovered to a normal level at 24 h postoperative. In 2 prospective studies published in 2016 [17] and 2017 [11], ACA was measured 1 month after V4c ICL implantation and found to have been narrowed by 34-42% and 39-45%, respectively. In those studies, the ACA at 1 month postoperative was more open than the early ACA at 1 h postoperative in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Both posterior chamber and iris-fixed PIOLs seem satisfactory options to treat high myopia [ 1 4 , 10 , 23 25 ], with no differences in efficacy or safety detected in a recent meta-analysis. [ 26 ] Our findings point to different AH flow behaviour and different WSS produced by this flow on the endothelium and crystalline lens depending on the type of lens implanted.…”
Section: Discussionmentioning
confidence: 99%
“…Iridocorneal angle width was set at 30 degrees [ 10 ]. For this we had to modify the angle using the software to adjust it to the high vault.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the 2-year follow-up of these patients evidenced angle closure stabilization (AOD at month 369 was ±170 vs. 354 ± 152 at 2 years; p = 1,0). 60 TIA correlated with the lens vault 2 years after surgery (R = −0.609; p < 0.001). In addition, iris-trabecular contact was observed in 8 of the 54 studied eyes in the first month after ICL implant which did not progress at 2 years after said implant.…”
Section: Assessment Of Angle Opening Modificationsmentioning
confidence: 97%