2023
DOI: 10.1016/j.echo.2023.02.012
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Ventricular Geometric Characteristics on Myocardial Stiffness Assessment Using Shear-Wave Velocity in Healthy Children and Young Adults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 34 publications
0
1
0
Order By: Relevance
“…However, we believe the guiding effect in the current study is minimal as the wall thickness (9 mm in baseline, see Table 1 ) is larger than (i) the wavelength (± 6.5 mm on average in Fig. 2 ), which is the typical criterion for the existence of guided waves, and (ii) the recently presented cut-off of 4.4 mm (age > 1 month) by Malik et al 30 for which diastolic speed no longer depended on wall thickness in a multivariate linear analysis for their (unreported) shear wave frequencies.…”
Section: Discussionmentioning
confidence: 54%
“…However, we believe the guiding effect in the current study is minimal as the wall thickness (9 mm in baseline, see Table 1 ) is larger than (i) the wavelength (± 6.5 mm on average in Fig. 2 ), which is the typical criterion for the existence of guided waves, and (ii) the recently presented cut-off of 4.4 mm (age > 1 month) by Malik et al 30 for which diastolic speed no longer depended on wall thickness in a multivariate linear analysis for their (unreported) shear wave frequencies.…”
Section: Discussionmentioning
confidence: 54%
“…16 Associado a tais fatores técnicos, o tecido cardíaco é essencialmente anisotrópico, com diferentes camadas, de paredes finas e com movimentação própria, 17 variáveis que podem influenciar adicionalmente na velocidade de propagação da onda de cisalhamento. Além disso, as alterações geométricas já demonstraram impacto nessas medidas, 18 bem como aumentos de pré-carga. 17 Esses fatores mecânicos limitam a utilização do módulo de Young para obtenção da rigidez miocárdica, pois essa equação não os considera.…”
Section: Desafios Para Sua Utilizaçãounclassified
“…16 Associated with such technical factors, cardiac tissue is essentially anisotropic, with different layers, thin walls, and its own movement patterns, 17 variables that can influence shear wave propagation speed. Furthermore, it has been shown that both geometric changes 18 and increased preload 17 affect…”
Section: Challenges To Using Shear Wave Elastographymentioning
confidence: 99%