2022
DOI: 10.4187/respcare.10065
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Unintentional Air Leaks on Automatic Positive Airway Pressure Device Performance in Simulated Sleep Apnea Events

Abstract: BACKGROUND: Positive airway pressure (PAP) is the accepted standard treatment for obstructive sleep apnea. In the last decades, automatic PAP (APAP) adjustment modes have been increasingly used. Pressure auto adjustment offers better comfort to the patient and represents a valuable help for the clinician to provide optimal treatment. However, device performance differs among manufacturers. Furthermore, the success of the therapy relies greatly on unintentional air leak (UAL) level for many reasons, hence the i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…The four ventilators, with different upper airway patency determination algorithms, showed different performances under the simulated conditions [46]. The concomitant presence of unintentional leakage may also contribute to undesired responses of auto-EPAP algorithms [47].…”
Section: Autotitration Algorithms To Maintain Upper Airway Patencymentioning
confidence: 99%
“…The four ventilators, with different upper airway patency determination algorithms, showed different performances under the simulated conditions [46]. The concomitant presence of unintentional leakage may also contribute to undesired responses of auto-EPAP algorithms [47].…”
Section: Autotitration Algorithms To Maintain Upper Airway Patencymentioning
confidence: 99%
“…Unintentional leak is an important factor with respect to CPAP acceptance and adherence, impact on accuracy of event determination and adequacy of treatment, particularly in APAP mode. 10 However, a few trials have compared leak between APAP and fixed CPAP, finding no significant differences, and that leak mainly depended on mean pressure and interface type. 11 This study also withdrew patients with excessive leak, which would have affected the applicability of the data to the proportion of patients who require more attention to mask-fitting.…”
Section: Sleep Well With Home Automationmentioning
confidence: 99%
“…It would have been useful to compare differences between the two modes of CPAP and whether they correlated with the differences in the CPAP tolerance questionnaire, such as nasal complaints and dry mouth. Unintentional leak is an important factor with respect to CPAP acceptance and adherence, impact on accuracy of event determination and adequacy of treatment, particularly in APAP mode 10 . However, a few trials have compared leak between APAP and fixed CPAP, finding no significant differences, and that leak mainly depended on mean pressure and interface type 11 .…”
Section: Strength Limitations Future Researchmentioning
confidence: 99%