Abstract: Purpose To determine the impact of the Bayesian penalized likelihood (BPL) reconstruction algorithm in comparison to OSEM on hypoxia PET/CT images of NSCLC using 18F-MIZO and 18F-FAZA. Materials and methods Images of low-contrasted (SBR = 3) micro-spheres of Jaszczak phantom were acquired. Twenty patients with lung neoplasia were included. Each patient benefitted from 18F-MISO and/or 18F-FAZA PET/CT exams, reconstructed with OSEM and BPL. Lesion was considered as hypoxic if the lesion SUVmax > 1.4. A blind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
13
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 19 publications
(36 reference statements)
3
13
0
Order By: Relevance
“…The smoothing effect added further enhancement with increasing β values for the increased [ 11 C]PiB image noise caused by fewer counts due to the shorter half‐life of [ 11 C] than [ 18 F] 22 . Since the surrounding activity, as well as the desired count statistics and resolution differ among radiopharmaceutical tracers, 21,30 the β value of BPL should be optimized for [ 18 F]FDG and [ 11 C]PiB images 6,17,36 …”
Section: Discussionmentioning
confidence: 99%
“…The smoothing effect added further enhancement with increasing β values for the increased [ 11 C]PiB image noise caused by fewer counts due to the shorter half‐life of [ 11 C] than [ 18 F] 22 . Since the surrounding activity, as well as the desired count statistics and resolution differ among radiopharmaceutical tracers, 21,30 the β value of BPL should be optimized for [ 18 F]FDG and [ 11 C]PiB images 6,17,36 …”
Section: Discussionmentioning
confidence: 99%
“…The specific features for each radiotracer are not discussed here. Among them, [ 18 F]-MISO ( 18 F-fluoromisonidazole) has been identified as a robust marker of hypoxia [ 159 , 160 ] with good reproducibility [ 161 ] and validity [ 162 , 163 , 164 ], highlighting [ 18 F]-MISO as a potential hypoxia-relevant biomarker, especially in radiation management [ 165 ]. [ 18 F]-HX4 PET imaging also seems promising to document hypoxia in NSCLC [ 166 , 167 , 168 ].…”