2022
DOI: 10.11591/ijpeds.v13.i4.pp2296-2304
|View full text |Cite
|
Sign up to set email alerts
|

Impact of static synchronous compensator STATCOM installation in power quality improvement

Abstract: <span lang="EN-US">The present work investigates the flexible AC transmission system (FACTS) device's role to improve the voltage stability for a distribution network of various types of loads. Our analysis was based on using a static synchronous compensator (STATCOM) device over a test distribution system. Firstly, a detailed description of the mathematical model used in our system is presented. Then we studied the effect of inductive and capacitive loads with and without STATCOM. To investigate the eff… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 23 publications
(25 reference statements)
0
0
0
Order By: Relevance
“…It should be noted that in the study of dynamic stability, the linearized model of the system is used, and in order to design the controllers that dampen fluctuations based on FACTS devices, these devices must be included in the linear model of the system. Among the works in the field of linearization of FACTS devices, we can refer to [44], which deals with the linear modeling of synchronous series compensator (SSSC), static synchronous compensator (STATCOM), and UPFC in single-machine and multi-machine power systems and the modification of the Heffron-Phillips model so that all three devices have reached a similar structure with minor differences for the modified Heffron-Phillips model [1], [3], [10], [15], [17], [22], [25], [27], [31], [45]- [71]. In these articles, several methods have been used to select the feedback signal for the complementary controller.…”
Section: Introductionmentioning
confidence: 99%
“…It should be noted that in the study of dynamic stability, the linearized model of the system is used, and in order to design the controllers that dampen fluctuations based on FACTS devices, these devices must be included in the linear model of the system. Among the works in the field of linearization of FACTS devices, we can refer to [44], which deals with the linear modeling of synchronous series compensator (SSSC), static synchronous compensator (STATCOM), and UPFC in single-machine and multi-machine power systems and the modification of the Heffron-Phillips model so that all three devices have reached a similar structure with minor differences for the modified Heffron-Phillips model [1], [3], [10], [15], [17], [22], [25], [27], [31], [45]- [71]. In these articles, several methods have been used to select the feedback signal for the complementary controller.…”
Section: Introductionmentioning
confidence: 99%