2014
DOI: 10.1016/j.enconman.2014.04.008
|View full text |Cite
|
Sign up to set email alerts
|

Impact of shadow on the performances of a domestic photovoltaic pumping system incorporating an MPPT control: A case study in Bejaia, North Algeria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(20 citation statements)
references
References 30 publications
0
19
0
1
Order By: Relevance
“…Based on the review conducted, the highest system efficiency of 7% was observed for a system using helical pumps providing 0-8.4 l/min of flowrate in the Amarillo Texas region [35]. The highest average flowrate of 2600 l per hour was quoted to be generated for a 990 Wp system in Algeria with 11 m head giving a productivity of 9498.030 m 3 /kWp per year, the efficiency of the system was 1.299% without shading and 0.83% with shading [36]. The most extensive research was conducted on a 3-5% efficient system with a size of 2kWp capable of water head of 5-125 m and was conducted in seven different countries however, this research was done 20 years ago [37].…”
Section: Pv Irrigation Systems Performancementioning
confidence: 75%
“…Based on the review conducted, the highest system efficiency of 7% was observed for a system using helical pumps providing 0-8.4 l/min of flowrate in the Amarillo Texas region [35]. The highest average flowrate of 2600 l per hour was quoted to be generated for a 990 Wp system in Algeria with 11 m head giving a productivity of 9498.030 m 3 /kWp per year, the efficiency of the system was 1.299% without shading and 0.83% with shading [36]. The most extensive research was conducted on a 3-5% efficient system with a size of 2kWp capable of water head of 5-125 m and was conducted in seven different countries however, this research was done 20 years ago [37].…”
Section: Pv Irrigation Systems Performancementioning
confidence: 75%
“…3 Many studies have focused on the performance of PVPS. [4][5][6][7][8][9][10] Such studies lead to the conclusion that PVPSs are more feasible than diesel-generated systems. They also indicate that the average daily water flow rate is in the range of 5.333 to 26.022 m 3 /kWp and that the overall efficieny of the system is in the range of 1.299% to 5%.…”
Section: Discussionmentioning
confidence: 99%
“…Many studies have focused on the performance of PVPS . Such studies lead to the conclusion that PVPSs are more feasible than diesel‐generated systems.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, the model which gives P (Q) of the pump motor unit for different pumping heights has been developed by [15].…”
Section: Motor-pump Modelizationmentioning
confidence: 99%