Impact of shading on a flat CPV system for façade integration

Abstract: Recently adopted energy efficiency policies in the EU induce a movement towards energy-neutral buildings. Building integrated photovoltaics technology connects with this ambition, as aside from the generation of electrical energy, it allows additional benefits such as heat generation, or daylight regulation by transmission of diffuse sunlight through transparent parts of the system. In this study three Concentrator Photocoltaic (CPV) system configurations that allow for the construction of semi-transparent bui… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 20 publications
1
8
0
Order By: Relevance
“…Notably, a portion of diffuse sunlight can be absorbed by the solar cells; however, the portion is negligibly small (less than 0.1% of total diffuse sunlight) in the case of high-concentration CPV (geometrical concentration ratio >100×) according to the acceptance angle limit of the solar concentrator. 15 Similar concepts have also been reported for building windows [16][17][18] and greenhouses. 19 Tripanagnostopoulos et al 16 proposed a CPV/thermal hybrid system with a Fresnel lens for building façades and experimentally evaluated the (a) temperature control performance of the building's interior space, (b) illumination control of the interior space, and (c) energy-harvesting performance (PV characteristics and heat collection) of the system.…”
Section: Module Conceptsupporting
confidence: 58%
See 1 more Smart Citation
“…Notably, a portion of diffuse sunlight can be absorbed by the solar cells; however, the portion is negligibly small (less than 0.1% of total diffuse sunlight) in the case of high-concentration CPV (geometrical concentration ratio >100×) according to the acceptance angle limit of the solar concentrator. 15 Similar concepts have also been reported for building windows [16][17][18] and greenhouses. 19 Tripanagnostopoulos et al 16 proposed a CPV/thermal hybrid system with a Fresnel lens for building façades and experimentally evaluated the (a) temperature control performance of the building's interior space, (b) illumination control of the interior space, and (c) energy-harvesting performance (PV characteristics and heat collection) of the system.…”
Section: Module Conceptsupporting
confidence: 58%
“…Similar concepts have also been reported for building windows and greenhouses . Tripanagnostopoulos et al proposed a CPV/thermal hybrid system with a Fresnel lens for building façades and experimentally evaluated the (a) temperature control performance of the building's interior space, (b) illumination control of the interior space, and (c) energy‐harvesting performance (PV characteristics and heat collection) of the system.…”
Section: Module Conceptmentioning
confidence: 83%
“…During the tests, the efficiency of the photovoltaic module increased by about 7% (reaching an h e of 22%). In Bunthof et al [47], they build up the examination dependent on three Concentrator Photovoltaic (CPV) systems arrangements that consider the development of semi-straightforward structure veneer components. The systems likewise are a Fresnel focal point based concentrator and a novel level planar optic concentrator.…”
Section: Integrated Photovoltaic Systemsmentioning
confidence: 99%
“…One of these challenges is partial shading which (Decker and Jahn 1997) have investigated. Furthermore, (Bunthof et al 2016) showed that partial shadowing is the primary parameter for decreasing the energy yield of PV arrays. (Woyte, Belmans, and Nijs 2003) studied one possible solution to overcome this challenge by using bypass diodes which allow PV arrays to produce at a lower capacity.…”
Section: Introductionmentioning
confidence: 99%
“…In this method, electrical current flows in a different path, and this causes a minor fraction of the total power. (Bunthof et al 2016) conducted a study that shows costs of the solar collectors increased by adding bypass diodes to the PV arrays. Considering all these parameters, this study focuses on a PVT receiver without a bypass system.…”
Section: Introductionmentioning
confidence: 99%