2016 IEEE Power and Energy Society General Meeting (PESGM) 2016
DOI: 10.1109/pesgm.2016.7741425
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Parameter Uncertainty on Power Flow accuracy in multi-terminal systems

Abstract: Abstract-Accurate power flow in a MT system can be achieved with droop controllers. However, almost all publications have assumed that the DC voltage, DC current and DC cable resistances can be measured with 100% accuracy. In this paper, a novel power flow solver is developed which enables the user to analyse the impact of these parameters on power flow accuracy. The developed Parameter Uncertainty Power Flow Solver (PU-PFS) is shown to be able to accurately calculate the power flow error for hundreds of param… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 10 publications
0
1
0
Order By: Relevance
“…On the other hand, long distance HVDC transmission proves to be advantageous over HVAC transmission due to the enhanced stability features, e.g., i) instantaneous precise control, ii) flexible connection among different synchronous zones, iii) enhanced transmission distance limit , whereas the reactive power flow due to large cable capacitance in submarine cables limits the maximum transmission distance, iv) capability of providing additional stability to the AC power network by constant frequency control, redistribution of power in the AC system and providing damping [9][10][11][12][13][14][15], [17]. Currently, there are three major manufacturers of VSC-HDVC systems; i.e.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, long distance HVDC transmission proves to be advantageous over HVAC transmission due to the enhanced stability features, e.g., i) instantaneous precise control, ii) flexible connection among different synchronous zones, iii) enhanced transmission distance limit , whereas the reactive power flow due to large cable capacitance in submarine cables limits the maximum transmission distance, iv) capability of providing additional stability to the AC power network by constant frequency control, redistribution of power in the AC system and providing damping [9][10][11][12][13][14][15], [17]. Currently, there are three major manufacturers of VSC-HDVC systems; i.e.…”
Section: Introductionmentioning
confidence: 99%