Impact of noise related waveforms on long term field leakage current measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
2

Year Published

2011
2011
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(18 citation statements)
references
References 25 publications
0
16
0
2
Order By: Relevance
“…Calculating the correlation coefficient using the data ac quired in the experiment suggests that the correlation coef ficient is not sensitive to typical insulator noises consisting of random number of minor peaks in low amplitudes [15]. Therefore, it avoids preprocessing of the data by filtering the noise which induces information loss.…”
Section: Defining the Nonlinearity Measurementioning
confidence: 99%
“…Calculating the correlation coefficient using the data ac quired in the experiment suggests that the correlation coef ficient is not sensitive to typical insulator noises consisting of random number of minor peaks in low amplitudes [15]. Therefore, it avoids preprocessing of the data by filtering the noise which induces information loss.…”
Section: Defining the Nonlinearity Measurementioning
confidence: 99%
“…Typical noise (noise which is always present) consists of random minor peaks that exhibit amplitude in the range of 1mA, as illustrated in Figure 8A and Figure 8B. That means that measurements in the typical noise area are usually incoherent and that, since meagre or no activity is the usual case, a large number of typical noise waveforms are recorded [9]. Single point noise results to a single point recorded far from the rest of the waveform.…”
Section: Wwwetasrcom Pylarinos Et Al: Investigation Of Lc Waveforms Recorded In a Coastal Hv Substationmentioning
confidence: 99%
“…The acquired data are transmitted to a central data acquisition system (DAS). The waveform portraying the highest LC peak value in a user-defined time window is recorded [9]. Each waveform has time duration of 480ms.…”
Section: Experimental Set Upmentioning
confidence: 99%
See 1 more Smart Citation
“…Several extracted values are commonly used [5] and advanced pattern recognition techniques have also been proposed [6][7]. Further, the size of the gathered data [8] and noise is always an issue [9]. Therefore, a leakage current monitoring system should be as flexible as possible in order to cope with different testing scenarios and to be able to incorporate future processing techniques.…”