2022
DOI: 10.1016/j.isci.2022.103828
|View full text |Cite
|
Sign up to set email alerts
|

Impact of myocardial reperfusion on human plasma lipidome

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 45 publications
0
8
0
Order By: Relevance
“…Frozen plasma samples were thawed for nearly 20 min. Lipids were extracted using chloroform and methanol as previously described [ 18 , 19 ]. Briefly, 10 μL of plasma was added to 200 μL of chloroform/methanol (2:1, v / v ) along with 30 μL of internal lipid standards (ISTD) in Eppendorf tubes, vortexed for 10 min, and sonicated in a water bath at room temperature (RT) for 30 min.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Frozen plasma samples were thawed for nearly 20 min. Lipids were extracted using chloroform and methanol as previously described [ 18 , 19 ]. Briefly, 10 μL of plasma was added to 200 μL of chloroform/methanol (2:1, v / v ) along with 30 μL of internal lipid standards (ISTD) in Eppendorf tubes, vortexed for 10 min, and sonicated in a water bath at room temperature (RT) for 30 min.…”
Section: Methodsmentioning
confidence: 99%
“…The lipidomic profiling was performed using a Prominence chromatographic system (Shimadzu Corporation, Canby, OR, USA) coupled with an AbSciex 4000 QTRAP triple quadrupole mass spectrometer (AB Sciex, Framingham, MA, USA). The entire LC/MS methodology for this work, including details of ISTD, quality control, and data processing, are described in detail in our previously published work [ 18 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Lipid internal standards (ISTD) were either odd-chain or deuterated and were not present endogenously. Samples were transferred into the micro insert in sample vials for lipid analysis (for details on lipid abbreviations, chemical information, and LC-MS conditions for each lipid species, refer to Supplementary Table Lipids were separated on a reverse-phase liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) platform using a Prominence chromatographic system (Shimadzu Corporation, OR, USA) as previously described [156]. Instrument control and data processing were done with Analyst v1.…”
Section: Liquid Chromatography Tandem Mass Spectrometry Analysis Of L...mentioning
confidence: 99%
“…4).Lipids were separated on a reverse-phase liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) platform using a Prominence chromatographic system (Shimadzu Corporation, OR, USA) as previously described[156]. Instrument control and data processing were done with Analyst v1.6 and MultiQuant v2.1 software (AB Sciex, MA, USA).…”
mentioning
confidence: 99%