2020
DOI: 10.1186/s41747-020-00184-z
|View full text |Cite
|
Sign up to set email alerts
|

Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT

Abstract: Background We investigated the impact of varying contrast medium (CM) densities and x-ray tube potentials on contrast enhancement (CE), image quality and radiation dose in thoracic computed tomography (CT) using two different scanning techniques. Methods Seven plastic tubes containing seven different CM densities ranging from of 0 to 600 HU were positioned inside a commercial chest phantom with padding, representing three different patient sizes. Helical scans of the phantom in single-source mode were obtain… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 41 publications
0
12
0
Order By: Relevance
“…Iodine is an alternative candidate that exhibits a broad antibacterial spectrum and has been used as a skin disinfectant for a long time [36]. In other aspects, iodine is an essential element in the living body and is utilized in catheter angiograms at high concentrations (300 mg I/mL and above) in vivo [37], demonstrating the cytocompatibility of iodine. A few reports demonstrate iodine being introduced into metal surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Iodine is an alternative candidate that exhibits a broad antibacterial spectrum and has been used as a skin disinfectant for a long time [36]. In other aspects, iodine is an essential element in the living body and is utilized in catheter angiograms at high concentrations (300 mg I/mL and above) in vivo [37], demonstrating the cytocompatibility of iodine. A few reports demonstrate iodine being introduced into metal surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…However, the majority (56%) of the respondents used flexible kV strategies. The use of lower kVp has been reported to reduce both radiation dose and CM load in chest CT, while maintaining image quality (50,51). Especially for vascular CT examinations, lower kVp settings are advantageous as higher noise is counterbalanced by higher vascular attenuation (52).…”
Section: Discussionmentioning
confidence: 99%
“…The FD of the eciFD protocol is likely to change with the use of saline flushes [ 29 , 30 ] and the CM dose may be reduced. [ 2 , 10 ]…”
Section: Limitationsmentioning
confidence: 99%