Healthy, Intelligent and Resilient Buildings and Urban Environments 2018
DOI: 10.14305/ibpc.2018.ie-1.05
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Indoor Temperature and CO2 Levels on Occupant Thermal Perception and Cognitive Performance of Adult Female Students in Saudi Arabia

Abstract: Due to hot arid climate in Jeddah, Saudi Arabia, occupants rely on air conditioning (AC) to provide both ventilation requirements and thermal comfort. It is believed that this total reliance on AC have also a significant effect on thermal sensation as well as cognitive performance of building occupants. Using a multi-variable multilevel statistical analysis, the effects of classroom temperature and CO2 levels on cognitive performance were estimated. Eight neurobehavioral cognitive tests were used to evaluate c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
19
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(19 citation statements)
references
References 7 publications
0
19
0
Order By: Relevance
“…The reported CO 2 concentration in the identified studies should be considered as an indicator of ventilation adequacy, which can be related to human bio‐effluents, but also to material emissions, chemicals used indoors, as well as other indoor sources of pollutants. The negative effect of elevated concentrations of bio‐effluents, but not pure CO 2 , and other constituents on cognitive performance is also confirmed by Zhang et al 52 The cognitive performance of students can decline by as much as 13% ( P < 0.001) when the CO 2 concentration increases from 600 to 1000 ppm 22,23 . However, this concentration of CO 2 still meets prevailing guidelines 53 .…”
Section: Discussionmentioning
confidence: 67%
See 4 more Smart Citations
“…The reported CO 2 concentration in the identified studies should be considered as an indicator of ventilation adequacy, which can be related to human bio‐effluents, but also to material emissions, chemicals used indoors, as well as other indoor sources of pollutants. The negative effect of elevated concentrations of bio‐effluents, but not pure CO 2 , and other constituents on cognitive performance is also confirmed by Zhang et al 52 The cognitive performance of students can decline by as much as 13% ( P < 0.001) when the CO 2 concentration increases from 600 to 1000 ppm 22,23 . However, this concentration of CO 2 still meets prevailing guidelines 53 .…”
Section: Discussionmentioning
confidence: 67%
“…However, this concentration of CO 2 still meets prevailing guidelines 53 . High CO 2 concentrations of 1800 ppm might affect cognitive performance with 24% ( P < 0.001) 22,23 . The influence of high CO 2 concentrations, as proxy for the IAQ, was higher on complex and memory‐oriented than for vigilance tasks.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations