Impact of Improved Calibration of a NEO HySpex VNIR-1600 Sensor on Remote Sensing of Water Depth

Abstract: This paper investigates at the example of bathymetry how much an application can profit from comprehensive characterizations required for an improved calibration of data from a state-of-the-art commercial hyperspectral sensor. A NEO HySpex VNIR-1600 sensor is used for this paper, and the improvements are based on measurements of sensor properties not covered by the manufacturer, in particular, detector nonlinearity and stray light. This additional knowledge about the instrument is used to implement corrections… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 27 publications
(49 reference statements)
0
14
0
Order By: Relevance
“…DLR Remote Sensing Technology Institute., 2016). Since an in depth treatment of the afore mentioned e orts can be found in Lenhard, Baumgartner, & Schwarzmaier (2015) and Lenhard, Baumgartner, Gege, et al (2015), the interested reader is referred to these publications for details. Section 2.2 is dedicated to the description of the navigation system used for absolute georeferencing of the acquired image data.…”
Section: System Overviewmentioning
confidence: 99%
See 1 more Smart Citation
“…DLR Remote Sensing Technology Institute., 2016). Since an in depth treatment of the afore mentioned e orts can be found in Lenhard, Baumgartner, & Schwarzmaier (2015) and Lenhard, Baumgartner, Gege, et al (2015), the interested reader is referred to these publications for details. Section 2.2 is dedicated to the description of the navigation system used for absolute georeferencing of the acquired image data.…”
Section: System Overviewmentioning
confidence: 99%
“…In order to correct detector non-linearity and stray light, several measurements were performed in cooperation with PTB within the framework of the EURAMET project. Lenhard, Baumgartner, Gege, et al (2015) elaborate on the associated methods and discuss the achievable improvements for the exemplary application of inland water depth retrieval.…”
Section: Hyspex Vnir-1600mentioning
confidence: 99%
“…• On the improvement that can be achieved through thorough hyperspectral sensor calibration (Lenhard, Baumgartner, Gege, et al, 2015).…”
Section: Selected Further Reading and Contact Detailsmentioning
confidence: 99%
“…Although the precision reflectance model of buildings and canopies [8,9] and the mixing model of minerals (such as the Hapke model [10,11]) have been developed, and the precision model of a spectrometer can also be specifically built [12], it is still important to measure reflected radiance in a hardware-in-the-loop (HWIL) simulation when researching the influence of environment, such as heavy metal toxicity in plants, nonlinear mixing of minerals, or weathered minerals [13,14,15,16,17,18,19,20,21,22]. The traditional approaches include conducting flight campaigns over experimental sites [13,14,15] and experiments in labs [16,17,18,19,20,21,22].…”
Section: Introductionmentioning
confidence: 99%
“…The traditional approaches include conducting flight campaigns over experimental sites [13,14,15] and experiments in labs [16,17,18,19,20,21,22]. The flight campaign approach has several shortcomings such as the great expense, time consumption, the complexity and difficulty of making simultaneous in-situ measurements of atmospheric parameters and ground reflective characteristics.…”
Section: Introductionmentioning
confidence: 99%