Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1016/j.enbuild.2021.110738
|View full text |Cite
|
Sign up to set email alerts
|

Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(22 citation statements)
references
References 15 publications
0
17
0
Order By: Relevance
“…IJV system not only consumed less energy consumption than MV, but also overcame the disadvantage that DV was not applicable for heating in winter [ 37 , 38 ]. This was because IJV had a large supply momentum, which could prevent the hot air flow from rising too fast due to buoyancy and maintain hot air stay for a long time in the personnel area [ 60 ]. IJV could provide excellent IAQ and virus spread control ability as it could offer smaller particle concentration and mean age of air (MAA) [ 59 ].…”
Section: Categories Of Different Ventilation Modesmentioning
confidence: 99%
See 1 more Smart Citation
“…IJV system not only consumed less energy consumption than MV, but also overcame the disadvantage that DV was not applicable for heating in winter [ 37 , 38 ]. This was because IJV had a large supply momentum, which could prevent the hot air flow from rising too fast due to buoyancy and maintain hot air stay for a long time in the personnel area [ 60 ]. IJV could provide excellent IAQ and virus spread control ability as it could offer smaller particle concentration and mean age of air (MAA) [ 59 ].…”
Section: Categories Of Different Ventilation Modesmentioning
confidence: 99%
“…The air age and CO 2 concentration decreased with the height increase of air outlet, and the result reached the standard requirement at about 1.2 m [ 35 ]. In addition, the shape and number of air outlets could be optimized to provide better results in pollutant removal and air exchange efficiency [ 60 ]. By increasing ceiling exhausts, the MAA could be reduced by up to 54%, the residence time of indoor air was shortened and the inhaled air quality by occupants was better.…”
Section: Impacts On Thermal Comfort Air Quality and Virus Spread Controlmentioning
confidence: 99%
“…The model was established according to the measured data and imported into ANSYS. According to the method provided by Arturs et al, the grid was set and divided, and finite element simulation analysis technology was used to analyze the indoor temperature [ 63 ]. The k-epsilon format was selected for the model, which is conducive to a more stable model analysis.…”
Section: Methodsmentioning
confidence: 99%
“…The grid setting in ANSYS software is very important, which determines the accuracy of the numerical simulations. Arturs et al [ 63 ] used 1.54, 1.92, 0.55, 0.98, 2.09, and 0.34 million hexagonal sections to divide the grid. In this research, mapped meshing and local refinement were selected.…”
Section: Methodsmentioning
confidence: 99%
“…For many years, building fabric elements also have been investigated in climate chambers, most often in quasi-stationary conditions. Such investigations deal with many problems related to building physics, energy performance of buildings, including all kinds of building fabric and thermal insulation [ 66 , 67 , 68 , 69 ], and the effect of ventilation on thermal comfort and indoor air quality (IAQ), particularly in office buildings [ 70 ]. The advantage of tests conducted in climate chambers over in situ tests in buildings is that they are independent of the weather conditions and therefore can be conducted practically all year round, whereby they are not limited to only the heating season and can be carried out for a set difference in air temperature between the two sides of a building enclosure.…”
Section: Introductionmentioning
confidence: 99%