2021
DOI: 10.1177/2045894020985345
|View full text |Cite
|
Sign up to set email alerts
|

Impact of human behavior on inspiratory flow profiles in patients with pulmonary arterial hypertension using AOS™ dry powder inhaler device

Abstract: Relative to healthy subjects, patients with pulmonary arterial hypertension often present with decreased respiratory muscle strength, resulting in decreased maximum inspiratory pressure. Little is known about the impact of reduced respiratory muscle strength on the ability to achieve the peak inspiratory pressures needed for effective drug delivery when using portable dry powder inhalers (≥1.0 kPa). The objective of this study was to assess the impact of inhaler resistance and patient instruction on the inspir… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 25 publications
0
12
0
Order By: Relevance
“…Sahay et al [ 131 ] studied the inspiratory flow profiles of 35 adult patients with pulmonary arterial hypertension (PAH) using variants of the RS01 DPI that had resistance values between 0.017 and 0.051 kPa 0.5 L −1 min. Mean Vi values increased from 1.7 to 1.9 L as the resistance of the device decreased.…”
Section: Increasing Tld and Product Density In Spray Dried Powdersmentioning
confidence: 99%
See 1 more Smart Citation
“…Sahay et al [ 131 ] studied the inspiratory flow profiles of 35 adult patients with pulmonary arterial hypertension (PAH) using variants of the RS01 DPI that had resistance values between 0.017 and 0.051 kPa 0.5 L −1 min. Mean Vi values increased from 1.7 to 1.9 L as the resistance of the device decreased.…”
Section: Increasing Tld and Product Density In Spray Dried Powdersmentioning
confidence: 99%
“…With the higher resistance DPI, the mean Vi decreased from 1.8 to 1.2 L when FEV 1 values were decreased from >60% predicted to <50% predicted. Adult patients with PAH have lower inhaled volumes than adults with asthma, COPD, CF, or Parkinson’s disease, due in part to most PAH patients being female [ 131 ].…”
Section: Increasing Tld and Product Density In Spray Dried Powdersmentioning
confidence: 99%
“…Even the high 42 mg requires only two inhalations from two capsules. Sahay et al [132] studied the inspiratory flow profiles of 35 adult patients with pulmonary arterial hypertension (PAH) using variants of the RS01 DPI that had resistance values between 0.017 and 0.051 kPa 0.5 L -1 min. Mean Vi values increased from 1.7 L to 1.9 L as the resistance of the device decreased.…”
Section: Inhaled Volumes Of Patientsmentioning
confidence: 99%
“…With the higher resistance DPI, the mean Vi decreased from 1.8 L to 1.2 L when FEV1 values were decreased from >60% predicted to <50% predicted. Adult patients with PAH have lower inhaled volumes than adults with asthma, COPD, CF, or Parkinson's disease, due in part to most PAH patients being female [132].…”
Section: Inhaled Volumes Of Patientsmentioning
confidence: 99%
“…Indeed, most children ages six and above exceed a pressure drop of 1 kPa when using passive DPIs [51][52][53][54]. This is especially true for children using higher resistance DPIs, as subjects tend to provide greater inspiratory effort when using a higher resistance device [55][56][57][58][59].…”
Section: Total Lung Dose Of Cpi In Idealized Anatomical Throat Modelsmentioning
confidence: 99%