2017
DOI: 10.1109/access.2017.2682260
|View full text |Cite
|
Sign up to set email alerts
|

Impact of High PV Penetration on the Inter-Area Oscillations in the U.S. Eastern Interconnection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
55
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 87 publications
(56 citation statements)
references
References 28 publications
1
55
0
Order By: Relevance
“…The basic concept of the adopted droop control is shown in Fig. 6 and the typical droop characteristics [37] can be written as in (5): where, f ref is the frequency reference (1pu), dp ref is the active power reference based on power-frequency (P-f) droop controller, K bess−f is the droop parameter with the slope of 1 K bess−f . BESS droop characteristics (charging/discharging) can be demonstrated in three operating regions as shown in Fig.…”
Section: Bess Damping Controller With Feedback Signalsmentioning
confidence: 99%
See 2 more Smart Citations
“…The basic concept of the adopted droop control is shown in Fig. 6 and the typical droop characteristics [37] can be written as in (5): where, f ref is the frequency reference (1pu), dp ref is the active power reference based on power-frequency (P-f) droop controller, K bess−f is the droop parameter with the slope of 1 K bess−f . BESS droop characteristics (charging/discharging) can be demonstrated in three operating regions as shown in Fig.…”
Section: Bess Damping Controller With Feedback Signalsmentioning
confidence: 99%
“…Number of publications on frequency challenges related to PV penetration in power system are available. Stability studies by the authors in [3]- [5] argued that reduction in inertia increases frequency oscillations of the system. In addition, authors in [5] indicated that higher PV penetration induces dramatic frequency oscillation beyond grid operating standards that potentially threatens uninterrupted load supply.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As reported in in [82], the POD at PV is designed by using wide-area signal. The damping ratios of the local modes are slightly increased by the integration of POD at PV, while on [83,84] the global modes are improved for systems with high penetration of PV power plants.…”
Section: Rotor Angle Stabilitymentioning
confidence: 99%
“…The influence of the PV-based penetration on the grid oscillations and its dynamic stability will vary according to the changes in the system operating's condition, which is due to the effects of damping torque impact from the PV system which can be positive or negative. The most serious operating condition for the PV-based power generation unit will arise when the sign of the damping torque's contribution of the PV system is changing [83][84][85].…”
Section: Rotor Angle Stabilitymentioning
confidence: 99%