2022
DOI: 10.1016/j.jelectrocard.2022.05.008
|View full text |Cite
|
Sign up to set email alerts
|

Impact of device length on electrogram sensing in miniaturized insertable cardiac monitors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…To obtain large R-wave amplitudes, the ICM model investigated in the present study was designed with an extended sensing vector using a flexible antenna that increases the inter-electrode spacing up to approximately 70 mm, very close to the optimal distance suggested by experimental research ( 15 ). A recent study directly comparing long- and standard- (<50 mm) sensing-vector ICMs confirmed that the long vector can be a good solution to obtain large sECG amplitudes ( 8 ).…”
Section: Discussionmentioning
confidence: 98%
See 3 more Smart Citations
“…To obtain large R-wave amplitudes, the ICM model investigated in the present study was designed with an extended sensing vector using a flexible antenna that increases the inter-electrode spacing up to approximately 70 mm, very close to the optimal distance suggested by experimental research ( 15 ). A recent study directly comparing long- and standard- (<50 mm) sensing-vector ICMs confirmed that the long vector can be a good solution to obtain large sECG amplitudes ( 8 ).…”
Section: Discussionmentioning
confidence: 98%
“…The impact of body composition on sensing amplitude detected by the ICM was among the secondary endpoints of several previous studies. Although data from short-sensing-vector devices (Reveal LINQ) suggested an inverse relationship between R-wave amplitude and BMI ( 17 ), studies with long-sensing-vector ICMs were less conclusive ( 8 , 10 , 18 22 ) ( Table 5 ). Lacour et al ( 18 ) did not observe such relationship in a small cohort of 19 patients implanted with a previous device version (BioMonitor 2).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The provides larger amplitudes of the sECG on average compared with the standard sensing dipole of less than 50 mm. 15 Improvements in ICM algorithms could also have played a role. For instance, in line with a recent report, 16 we observed that the RhythmCheck feature showed…”
Section: Discussionmentioning
confidence: 99%