Immediate sealing of arterial puncture site following femoropopliteal angioplasty: A prospective randomized trial

Abstract: Compared with manual compression HPCD is faster and more accurate for sealing the arterial puncture defect following angioplasty. After an initial learning curve, it is easy to handle and time-saving as well as convenient for the patient. Furthermore, immediate and full anticoagulation is possible and arterial inflow is not compromised. A drawback is the necessity of an 8 Fr sheath. Nevertheless, the complication rate is comparably low for both methods.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…Furthermore, an increase in compression time leads to higher costs. 25,26 Access site complication rates .10% after interventional procedures can frequently be found in the literature. 27 Vascular closure devices (VCD) were introduced to reduce the time to hemostasis and enhance the safety of percutaneous interventions, as reflected in less bleeding and fewer access site complications.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, an increase in compression time leads to higher costs. 25,26 Access site complication rates .10% after interventional procedures can frequently be found in the literature. 27 Vascular closure devices (VCD) were introduced to reduce the time to hemostasis and enhance the safety of percutaneous interventions, as reflected in less bleeding and fewer access site complications.…”
Section: Discussionmentioning
confidence: 99%
“…Literature review for occurrence of puncture site-related complications during interventional procedures, either by manual compression or with a VCD, reveals comparable rates for hematoma (up to 16%), bleeding (up to 9%), and pseudoaneurysm (up to 8%). [25][26][27][28][29][30][31][32][39][40][41][42][43][44][45][46] Within the 4-EVER study, we evaluated the use of a complete low-profile approach during endovascular intervention. The only access site complications in this study with 4-F systems were hematoma (3.3%) at the puncture site not requiring surgical repair.…”
Section: Discussionmentioning
confidence: 99%
“…The details of Angio-Seal device deployment and its composition has been described previously. 28,29 In brief, the device consists of an absorbable intraluminal component (''anchor'') and a small collagen plug. The anchor is deployed intraluminally such that the arterial wall and the arteriotomy site are ''sandwiched'' between the anchor and the collagen plug, inducing hemostasis.…”
Section: Techniquementioning
confidence: 99%
“…Two trials 12 13 were further excluded due to zero events in both arms. Finally, 40 trials 6 7 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 were included in this meta-analysis. The screening process is shown in Fig.…”
Section: Resultsmentioning
confidence: 99%