2005
DOI: 10.1016/j.prosdent.2005.04.021
|View full text |Cite
|
Sign up to set email alerts
|

Immediate loading of single-tooth implants in the posterior region

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

8
68
0
11

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(91 citation statements)
references
References 0 publications
8
68
0
11
Order By: Relevance
“…Periotest® measures PS by assessing the damping capacity upon tapping against the implant and generating a PV. It has also been shown to be a reliable indicator in conventional and immediate loading (23). However, Osstell™ system has been proved to be more reliable compared to Periotest® in measuring dental implant stability (24).…”
Section: Discussionmentioning
confidence: 99%
“…Periotest® measures PS by assessing the damping capacity upon tapping against the implant and generating a PV. It has also been shown to be a reliable indicator in conventional and immediate loading (23). However, Osstell™ system has been proved to be more reliable compared to Periotest® in measuring dental implant stability (24).…”
Section: Discussionmentioning
confidence: 99%
“…It is worth pointing out that the bar's mechanical response was behind the scope of the present study and then the bar modeling has been performed with the only purpose to allow a suitable loading transfer towards the implant-bone coupled system. as the peri-implant bone geometries were arranged in order to match well-established clinical evidences associated with crestal bone loss and remodeling at the implant necks (Abboud et al, 2005;Degidi et al, 2009;Shin et al, 2006). Accordingly, for Nobel Biocare devices the peri-implant cortical geometries were modelled such that the first coil was always in contact with the compact bone layer, and a cratering morphology with a mean crestal bone loss of about 45% in thickness was considered.…”
Section: Computational Modelsmentioning
confidence: 99%
“…Se realizó toma de impresiones, prueba de rodillo y prueba de dientes en cera de forma convencional. 46 Calandriello incluía en su estudio sobre carga de molares mandibulares con implantes anchos con superficie TiUnite a 44 pacientes y 50 implantes rehabilitados con coronas provisionales en oclusión céntrica, el estudio ofrecía un seguimiento medio de sólo 6 meses sin pérdida de implantes. 26 En nuestro protocolo utilizamos habitualmente un implante por cada diente que vayamos a sustituir si el espacio protésico, el volumen óseo y la distancia biológica entre implantes y entre éstos y los dientes adyacentes es la adecuada.…”
Section: Figuraunclassified