1999
DOI: 10.1021/cr980137w
|View full text |Cite
|
Sign up to set email alerts
|

Imaging with Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
211
0
1

Year Published

2002
2002
2014
2014

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 288 publications
(217 citation statements)
references
References 192 publications
(379 reference statements)
0
211
0
1
Order By: Relevance
“…The quadrupole system suffers from loss of sensitivity at higher mass, but this is offset by the capability to perform MS/MS as needed. While time-of-flight mass spectrometers are more often employed for imaging tissue [12], performing simultaneous MS/MS and imaging with them is problematic.…”
Section: Secondary Ion Mass Spectrometermentioning
confidence: 99%
“…The quadrupole system suffers from loss of sensitivity at higher mass, but this is offset by the capability to perform MS/MS as needed. While time-of-flight mass spectrometers are more often employed for imaging tissue [12], performing simultaneous MS/MS and imaging with them is problematic.…”
Section: Secondary Ion Mass Spectrometermentioning
confidence: 99%
“…To make the sample preparation step easier, less time consuming, and reduce the risk of cross-contamination, we developed a simple version of the solvent-free sample preparation method, now called the vortex method [16]. Although the utility of solvent-free sample preparation for MALDI has been clearly demonstrated, the investigations into why it works and what impact these data have on our overall understanding of the MALDI process have only recently begun [17,18].To develop increased understanding of the utility of the solvent-free MALDI sample preparation method, we have investigated the morphology of these samples using different imaging experiments-optical imaging [19], scanning electron microscopy (SEM) [20], atomic force microscopy (AFM) [21], and time-of-flight secondary ion mass spectrometry (ToF-SIMS) [22]. Previous work has shown the utility of investigating MALDI sample morphology using imaging methods.…”
mentioning
confidence: 99%
“…To develop increased understanding of the utility of the solvent-free MALDI sample preparation method, we have investigated the morphology of these samples using different imaging experiments-optical imaging [19], scanning electron microscopy (SEM) [20], atomic force microscopy (AFM) [21], and time-of-flight secondary ion mass spectrometry (ToF-SIMS) [22]. Previous work has shown the utility of investigating MALDI sample morphology using imaging methods.…”
mentioning
confidence: 99%
“…This results in higher secondary ion yields and yield enhancements on silicon than aluminum substrates. S econdary ion mass spectrometry (SIMS) is widely used to study the chemical composition of surfaces in areas from biological systems to materials chemistry [1,2]. One of the problems with the SIMS analysis of surfaces is that low secondary molecular ion yields are often observed for atomic primary ion impacts.…”
mentioning
confidence: 99%
“…Examples of polyatomic ions that exhibit this behavior include Au n ϩ [3][4][5][6][7][8], (CsI) n Cs ϩ [3,9,10], C 60 ϩ [8,9,[11][12][13][14][15], SF 5 ϩ [16 -21], and Au n Ϫ [22,23]. Thus, using polyatomic projectiles can potentially improve secondary ion yields, which may lead to an increase in the maximum useful spatial resolution that can be achieved, currently ϳ200 nm [1]. To improve spatial resolution, we require both high secondary ion yields and primary ion beams with a small beam diameter.…”
mentioning
confidence: 99%