1991
DOI: 10.1016/0891-0618(91)90040-j
|View full text |Cite
|
Sign up to set email alerts
|

Imaging receptors by autoradiography: Computer-assisted approaches

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1993
1993
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…Emulsion-covered coverslips and subsequent microscopic examination have been widely used, especially in the initial studies. The introduction of tritium-sensitive sheet films for the visualization of the labeled receptors (Palacios et al, 1981) represented an important advance because of their ease of use and, more importantly, because they allow accurate, rapid, and relatively easy quantification of the densities of receptors with the help of computer-assisted image analysis systems (Kuhar et al, 1991 ;Palacios et al, 1991).…”
Section: Methods For the Visualization O F Neurotransmitter Receptorsmentioning
confidence: 99%
“…Emulsion-covered coverslips and subsequent microscopic examination have been widely used, especially in the initial studies. The introduction of tritium-sensitive sheet films for the visualization of the labeled receptors (Palacios et al, 1981) represented an important advance because of their ease of use and, more importantly, because they allow accurate, rapid, and relatively easy quantification of the densities of receptors with the help of computer-assisted image analysis systems (Kuhar et al, 1991 ;Palacios et al, 1991).…”
Section: Methods For the Visualization O F Neurotransmitter Receptorsmentioning
confidence: 99%
“…Thus, [ 3H]-esuadiol and [ 3HJ-moxestrol both give good results, albeit after a 3-month exposure as opposed to the 1-day exposure required with [ 12'I]-MIE2. Non-photographic image-enhancement techniques Kuhar et al, 1991) may provide a valuable adjunct to studies with 3H-labeled ligands to achieve shorter exposure times. Results with the commercially available iba-[ '2'I]-iodo-estradiol, by contrast, were not satisfactory.…”
Section: Discussionmentioning
confidence: 99%
“…During the last decade, autoradiograms on film or micro-autoradiograms on histological sections have been quantified using image analysers calibrated with known standards (Kuhar et al, 1991). The determination of receptor specificity and affinity became possible on very small structures of interest using quantitative *To whom correspondence should be addressed.…”
Section: Introductionmentioning
confidence: 99%