2007
DOI: 10.1117/12.732519
|View full text |Cite
|
Sign up to set email alerts
|

Imaging open-path Fourier transform infrared spectrometer for 3D cloud profiling

Abstract: An imaging open-path Fourier transform infrared (I-OP-FTIR) spectrometer is being developed for real-time threedimensional cloud profiling. The system employs a single modulator and a novel optical configuration which projects an array of angularly dispersed IR beams, each of which exhibits comparable throughput to a single channel OP-FTIR, to an array of respective retroreflector arrays remotely located at the opposite side of the test grid. The return light from each retroreflector array is imaged onto respe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 1 publication
(1 reference statement)
0
2
0
Order By: Relevance
“…Differential absorption lidar (DIAL) shifts the laser frequency onto and off an analyte absorption peak to derive the analyte absorption. An openpath FTIR array spectrometer has been reported that performs 3D profiling of atmospheric plumes in real time [74].…”
Section: Chemical Image Creation Using Remote Sensingmentioning
confidence: 99%
“…Differential absorption lidar (DIAL) shifts the laser frequency onto and off an analyte absorption peak to derive the analyte absorption. An openpath FTIR array spectrometer has been reported that performs 3D profiling of atmospheric plumes in real time [74].…”
Section: Chemical Image Creation Using Remote Sensingmentioning
confidence: 99%
“…In cases where multiple gases are addressed, there is typically a size and weight penalty because it often requires the integration of multiple lasers or resonant cavities and their associated optics. In scenarios with high intrinsic thermal contrast, such as monitoring exhaust plumes in industrial settings, a passive system can be used instead, which provides the ability to monitor a much broader range of gases with a reduced sensitivity 3,4,5 . Since the target chemicals and the measurement scenarios of interest to NASA may vary over time, OPTRA is currently developing a modular spectrometer for the detection of GHGs that can be reconfigured into an active in situ or passive remote sensor to provide the desired level of sensitivity and flexibility, thereby accommodating a wide range of research interests.…”
Section: Introductionmentioning
confidence: 99%