2007
DOI: 10.1016/j.ophtha.2006.05.078
|View full text |Cite
|
Sign up to set email alerts
|

Imaging of Trabeculectomy Blebs Using Anterior Segment Optical Coherence Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

15
143
3
7

Year Published

2008
2008
2020
2020

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 166 publications
(170 citation statements)
references
References 24 publications
15
143
3
7
Order By: Relevance
“…Obtaining preoperative knowledge of bleb structures appears feasible in planning safe surgery beforehand to reduce the risk of complications from manipulation. Noninvasive approaches to examine bleb include ultrasound biomicroscopy and AS-OCT. 1,2 In our case, multiloculated bleb structure of dissecting portion apart from the main cystic bleb was confirmed by preoperative AS-OCT imaging and histological study. Previous reports of overhanging bleb [3][4][5] stated that leaking was not a common complication even without the safety measure or suture.…”
Section: Commentsupporting
confidence: 65%
“…Obtaining preoperative knowledge of bleb structures appears feasible in planning safe surgery beforehand to reduce the risk of complications from manipulation. Noninvasive approaches to examine bleb include ultrasound biomicroscopy and AS-OCT. 1,2 In our case, multiloculated bleb structure of dissecting portion apart from the main cystic bleb was confirmed by preoperative AS-OCT imaging and histological study. Previous reports of overhanging bleb [3][4][5] stated that leaking was not a common complication even without the safety measure or suture.…”
Section: Commentsupporting
confidence: 65%
“…9,13 External bleb classifications 10,11 have been described to address the glaucoma surgery functionality and prognosis but they cannot assess the intrascleral bleb. Recently, the AS-OCT has been used to evaluate filtering blebs after trabeculectomy [2][3][4] and DS with collagen scleral implant. 5,6 The objective of this study was to perform an analysis of the relationship between DS blebs height with three different intrascleral implants and IOP using the Visante AS-OCT.…”
Section: Discussionmentioning
confidence: 99%
“…1 Anterior segment optical coherence tomography (AS-OCT) has been used to evaluate blebs after filtrating glaucoma surgery. [2][3][4][5][6] Glaucoma surgery long-term success is determined by the development of an adequate filtering bleb in both trabeculectomy and deep sclerectomy (DS).…”
Section: Introductionmentioning
confidence: 99%
“…7,8 However, the previous studies used two-dimensional (2D) OCT, so the filtration openings could not be identified because of the limited number of sections (a radial section perpendicular to the limbus and/or a section tangential to the limbus through the site of maximal bleb elevation). 7,8 With three-dimensional (3D) AS-OCT, aqueous outflow openings at the margin of scleral flaps can be visualized more clearly using en face OCT images.…”
Section: Introductionmentioning
confidence: 99%
“…7,8 However, the previous studies used two-dimensional (2D) OCT, so the filtration openings could not be identified because of the limited number of sections (a radial section perpendicular to the limbus and/or a section tangential to the limbus through the site of maximal bleb elevation). 7,8 With three-dimensional (3D) AS-OCT, aqueous outflow openings at the margin of scleral flaps can be visualized more clearly using en face OCT images. 9,10 In our previous studies we obtained 512 3D scans that were rotated using newly developed software (CASIA bleb-assessment software, Tomey) and matched with reconstructed C-scan images (tomographic image of the slice plane perpendicular to the depth direction) to precisely identify the filtration openings on the scleral flap.…”
Section: Introductionmentioning
confidence: 99%