Abstract: The observed changes in the cornea's birefringence properties indicate a change in the arrangement of collagen fibrils in the corneal stroma associated with keratoconus. PS-OCT may be a useful tool for the study and diagnosis of corneal disease.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
49
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 56 publications
(50 citation statements)
references
References 36 publications
(49 reference statements)
1
49
0
Order By: Relevance
“…This possibly indicates that multiple reflections at interfaces of lamellae or fibrils are the cause for depolarization. We want to point out that in vitro measurements of the cornea did not show depolarization from within the stroma [19,20,24]. This effect can only be observed when imaging is performed in vivo which has been outlined in a previous study using a time-domain PS-OCT instrument [36].…”
Section: Discussionmentioning
confidence: 77%
See 1 more Smart Citation
“…This possibly indicates that multiple reflections at interfaces of lamellae or fibrils are the cause for depolarization. We want to point out that in vitro measurements of the cornea did not show depolarization from within the stroma [19,20,24]. This effect can only be observed when imaging is performed in vivo which has been outlined in a previous study using a time-domain PS-OCT instrument [36].…”
Section: Discussionmentioning
confidence: 77%
“…When imaging the human cornea with PS-OCT, distinct patterns in retardation and axis orientation can be observed, as shown by previous studies [19][20][21][22][23], that arise from the corneal shape and the corresponding fibril orientation. These patterns are distorted in case of diseases like keratoconus [24,25], making this technique a promising method for corneal diagnostics.…”
Section: Introductionmentioning
confidence: 99%
“…4(c3) was caused by the calculation method of local birefringence shown in Eq. (19), where the multiplication of two pixels could enhance the speckle noise. By applying both processing methods, the best image quality of the local retardation was obtained as shown in Fig.…”
Section: Efficacy Of the Processing Methods In A Healthy Human Eyementioning
confidence: 99%
“…7(b3) had remaining speckle noise caused by the calculation method of local birefringence shown in Eq. (19). The coherent spatial Gaussian filter was effective to reduce it as shown in Fig.…”
Section: Measurements Of Known Samplesmentioning
confidence: 99%
See 1 more Smart Citation