Image quality of a portable X-ray device (Nomad Pro 2) compared to a wall-mounted device in intraoral radiography

Abstract: Objectives The aim of this study was to determine whether a handheld (HH) X-ray device (Nomad Pro 2) is capable of producing equivalent or even superior X-ray image quality in comparison to a wall-mounted (WM) dental X-ray unit (Heliodent Plus) on the basis of objectifiable image quality parameters. Methods Anatomical, radiological and biological dental X-ray image quality parameters of a handheld dental X-ray device (Nomad Pro 2, Kavo Kerr, Biberach, Germany) were compared to a standard wall-mounted dental X-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
5
0
4

Year Published

2021
2021
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(12 citation statements)
references
References 14 publications
3
5
0
4
Order By: Relevance
“…As HH devices are scarce in Western Europe, it is possible that operator training would significantly improve the precision of the aim. This is in conformity with other studies ( Gray et al, 2012 ; Nitschke et al, 2020 ). The studies of Ulusu et al (2010) and Nitschke et al (2020) described comparable image quality of HH and WM devices on digital radiographs ( Ulusu et al, 2010 ; Nitschke et al, 2020 ).…”
Section: Discussionsupporting
confidence: 94%
See 3 more Smart Citations
“…As HH devices are scarce in Western Europe, it is possible that operator training would significantly improve the precision of the aim. This is in conformity with other studies ( Gray et al, 2012 ; Nitschke et al, 2020 ). The studies of Ulusu et al (2010) and Nitschke et al (2020) described comparable image quality of HH and WM devices on digital radiographs ( Ulusu et al, 2010 ; Nitschke et al, 2020 ).…”
Section: Discussionsupporting
confidence: 94%
“…This is in conformity with other studies ( Gray et al, 2012 ; Nitschke et al, 2020 ). The studies of Ulusu et al (2010) and Nitschke et al (2020) described comparable image quality of HH and WM devices on digital radiographs ( Ulusu et al, 2010 ; Nitschke et al, 2020 ). The present results show that the accuracy of HH and WM devices seem comparable.…”
Section: Discussionsupporting
confidence: 94%
See 2 more Smart Citations
“…En relación con el kV, en los EP depende de la carga de la batería, a diferencia de los equipos fijos y móviles, que funcionan con corriente eléctrica (18). Si bien diversas investigaciones han encontrado una calidad de imagen aceptable al usar EP, similar a la obtenida con los equipos fijos (13,19,20), el inconveniente se presenta con el uso diario del equipo, que provoca una disminución en la carga de la batería. Por lo tanto, para evitar disminución en la calidad de imagen por un menor kV, se recomienda mantener siempre la batería con carga (21), una recarga regular y el uso de baterías más eficientes (22).…”
Section: Características Generalesunclassified