2008
DOI: 10.1259/dmfr/16770531
|View full text |Cite
|
Sign up to set email alerts
|

Image qualityvsradiation dose of four cone beam computed tomography scanners

Abstract: The best radiation dose vs image quality was found for the i-CAT.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
87
0
24

Year Published

2011
2011
2021
2021

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 134 publications
(112 citation statements)
references
References 18 publications
1
87
0
24
Order By: Relevance
“…However, it can be clear that the voxel size itself provides only a crude prediction of the spatial accuracy. ( 2 , 16 ) The voxel size, determined by the manufacturer, should ideally provide a balance between spatial resolution and noise. It is seen that for some devices, predefined exposure protocols using different mAs values are reconstructed at different voxel sizes.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…However, it can be clear that the voxel size itself provides only a crude prediction of the spatial accuracy. ( 2 , 16 ) The voxel size, determined by the manufacturer, should ideally provide a balance between spatial resolution and noise. It is seen that for some devices, predefined exposure protocols using different mAs values are reconstructed at different voxel sizes.…”
Section: Discussionmentioning
confidence: 99%
“…( 1 , 2 ) Three different aspects have to be considered in the optimization of an X‐ray imaging modality: quantification of the radiation dose and risk for patients, assessment of technical image quality, and assessment of diagnostic image quality. By means of an appropriate test object, the first and second aspect can be studied in one investigation process.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…O estudo atual confirma os resultados anteriores que demonstraram alta precisão de imagens obtidas com TCFC por meio de medidas lineares (Kobayshi et al, 2004;Lascala et al, 2004;Ludlow et al, 2007;Suomalainen et al, 2008;Loubele et al, 2008;Periago et al, 2008;Stratemann et al, 2008;Hassan et al, 2009;Lund et al, 2009;Brown et al, 2009;Damstra et al, 2010;Maloney et al, 2011;El-Beialy et al, 2011;Tomasi et al, 2011;Panzarella et al, 2011;Al-Ekrish, Ekran 2011;Timock et al, 2011;Engelbrecht et al, 2013;Waltrick et al, 2013;Kosalagood et al, 2014). Contribuindo para a consolidação da precisão das imagens de TCFC, análises geométricas das medidas também foram analisadas em alguns estudos (Marmulla et al, 2005;Baltrick et al, 2008;Primo et al, 2012) obtendo significativos resultados.…”
Section: Variação: Examinadores E Momentosunclassified