2009
DOI: 10.1582/leukos.2009.06.01005
|View full text |Cite
|
Sign up to set email alerts
|

Illuminance Uniformity Filter for Theatrical Lighting Fixture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2009
2009
2012
2012

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…of Equation ( 10) was used for UGR. Only Equation (2) was clearly defined as glare sensation, 8,[11][12][13][14][15][16] other formula terms used above for quantifying glare sensation were assumed in this study as an intermediate step to calculate the glare ratings. This assumption does not affect the final results of the calculation, because E d and E i in those terms are constants at each trial.…”
Section: Calculating Discomfort Glare Ratings Using Numerical Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…of Equation ( 10) was used for UGR. Only Equation (2) was clearly defined as glare sensation, 8,[11][12][13][14][15][16] other formula terms used above for quantifying glare sensation were assumed in this study as an intermediate step to calculate the glare ratings. This assumption does not affect the final results of the calculation, because E d and E i in those terms are constants at each trial.…”
Section: Calculating Discomfort Glare Ratings Using Numerical Methodsmentioning
confidence: 99%
“…[2][3][4][5][6][7] Unfortunately, the physiological and psychophysical mechanisms of discomfort glare are not yet well understood. 8 As a result, different glare indices have been individually developed in four fields to evaluate interior electric lighting, [9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] daylighting (windows), [28][29][30][31][32][33][34][35][36][37] exterior area lighting, [38][39][40] and roadway and traffic lighting. [41][42][43][44][45] In particular, for evaluating interior electric lighting, Guth 9 developed an index called visual comfort probability (VCP), based on the borderline between comfort and discomfort brightness (BCD), 10 (Equation ( 1)).…”
Section: Introductionmentioning
confidence: 99%
“…This finding was an interesting one, because the International Commission on Illumination recently published an extension to the discomfort glare metric that suggested that nonuniform sources should actually cause more discomfort than uniform ones. Currently, there are four publications from this work (Eble-Hankins and Waters 2004, 2009a, 2009b, 2009c.…”
Section: Development Of Researchmentioning
confidence: 99%