2021
DOI: 10.33271/mining15.04.108
|View full text |Cite
|
Sign up to set email alerts
|

Identifying the efficiency decrease factor of motors working under power harmornic in 660V electric mining grids

Abstract: Purpose. Identify the motors efficiency decrease factor corresponding to various values of load-carrying ratio. Methods. Basing on the onsite measurements of power harmonic in 660V low voltage (LV) grids in Vietnam underground mines, simulations have been done on MATLAB and compared with mathematical models. Verifying data will be implemented in Lab-measurements carried out on pumping system to reveal series of decreasing factors. Findings. Series factors present the relation of the level of powe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 10 publications
0
1
0
Order By: Relevance
“…required, regardless of earth fault types". In order to be eff ective, the grounding system itself must be maintained with a low or very low value of resistance in all its long-life time [9,10]. Moreover, in 660 V mining grid this system consisting of horizontal bar conductors interconnected with 4 th wire (or rod) of transmission cables is aimed to minimize ground potential rise as small/low as possible [11].…”
Section: Information Technologies Systems Analysis and Administrationmentioning
confidence: 99%
“…required, regardless of earth fault types". In order to be eff ective, the grounding system itself must be maintained with a low or very low value of resistance in all its long-life time [9,10]. Moreover, in 660 V mining grid this system consisting of horizontal bar conductors interconnected with 4 th wire (or rod) of transmission cables is aimed to minimize ground potential rise as small/low as possible [11].…”
Section: Information Technologies Systems Analysis and Administrationmentioning
confidence: 99%
“…Nowa days, mining capacity is getting bigger and bigger, the mining depth is increasing, this leads to the use of DC power trans mission in network mining with many benefits both in terms of economy and technique [11][12][13]. For long cable networks, the DC power transmission brings many benefits such as reducing the influence of harmonics, reducing voltage loss, power loss in the power network, and reducing cable costs [14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…It should be noted that interharmonics (IH), most frequently occurring in electrical devices, indicate the greatest negative impact [13][14][15]. Such processes are also observed in the energy supply of complex thermochemical processes [16,17].…”
mentioning