47th AIAA Fluid Dynamics Conference 2017
DOI: 10.2514/6.2017-3309
|View full text |Cite
|
Sign up to set email alerts
|

Identifying Dynamic Modes of Separated Flow Subject to ZNMF-Based Control from Surface Pressure Measurements

Abstract: Fluid systems are most efficient for fully attached flows, and designers therefore seek to avoid flow separation. Active flow control can help achieve this goal, and closed-loop control offers improved performance at off-design conditions. However, this requires feedback of accurate state estimates to the controller in real time. This motivates a physics-based, state-estimation technique that economically extracts key dynamical features of the flow. This work aims to extract dynamical characteristics of a lami… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 35 publications
(54 reference statements)
0
16
0
Order By: Relevance
“…Starting from the 13th eigenvalueμ 13 ≈ µ 6,0 = γ 6 δ 0 = (0.9) 6 (0.8) 0 = 0.531441, the error dramatically increases, which implies that the remaining eigenfunctions cannot be accurately identified using EDMD with this choice of observables. This is expected, as monomials up to degree 5 can not represent the eigenfunction ϕ 6,0 (x) = x 6 1 . This comparison gives us confidence in the reliability of the accuracy criterion.…”
Section: Validating the Accuracy Criterionmentioning
confidence: 97%
See 1 more Smart Citation
“…Starting from the 13th eigenvalueμ 13 ≈ µ 6,0 = γ 6 δ 0 = (0.9) 6 (0.8) 0 = 0.531441, the error dramatically increases, which implies that the remaining eigenfunctions cannot be accurately identified using EDMD with this choice of observables. This is expected, as monomials up to degree 5 can not represent the eigenfunction ϕ 6,0 (x) = x 6 1 . This comparison gives us confidence in the reliability of the accuracy criterion.…”
Section: Validating the Accuracy Criterionmentioning
confidence: 97%
“…The average separation bubble length is L sep = 0.2c. More information regarding the separation system and the flat plate model can be found in [6]. PIV velocity data is sampled at f s = 1600 Hz, with a resolution of 319 × 62 pixels.…”
Section: Canonical Separated Flowmentioning
confidence: 99%
“…The microphones are placed at the centerline of the plate, between x/c = 0.70 and 0.94, with a spacing of 0.02. More details regarding this microphone array can be found in [28]. These 13 microphone signals provide the data we use for online DMD.…”
Section: Pressure Fluctuations In a Separation Bubblementioning
confidence: 99%
“…Prior to applying online DMD, the microphone signals are conditioned to remove external contaminating sources. This process is described in [28]. We collect pressure data for a total time of T = 10 sec.…”
Section: Pressure Fluctuations In a Separation Bubblementioning
confidence: 99%
“…A large portion of the turbulent flow controllers are derived from a reduced-order model, using previous knowledge of the physics of the flow. The physical analysis of the flow can yield simple models leading to efficient control laws [48,16]. The second option is system identification using experimentally obtained black-box models (seeks to build an input-output model of the flow from empirical observations).…”
Section: Introductionmentioning
confidence: 99%